Ultrasonic Medical Focusing Spherical Piezo for Diagnostic Equipment
WuHan Piezohannas Tech.Co .,Ltd is a manufactuer of piezoelectric ceramics ,ultrasonic transducers with strong technology force.With a quality management system and research & development sector,our products are extensively used in most applications.
Working Frequency : 1 ~ 10 MHz (Selectable)
Aperture size : Diameter 20 ~ 70mm(Selectable)
Focal length: 10 ~ 100 mm (Selelctable)
Strong Electrode: Silvering ,Nickel, Titanium Alloys
Long Lifetime: high power pulses>15000
PZT Soft Material:
"Soft" PZT materials | The type of soft material | ||||||||
Properties | PSnN-5 | PLiS-51 | PZT-51 | PZT-52 | PZT-53 | PZT-5H | PZT-5X | ||
Dielectric Constant | ɛTr3 | 1600 | 2000 | 2200 | 2400 | 2600 | 3200 | 4500 | |
Coupling factor | KP | 0.6 | 0.62 | 0.62 | 0.63 | 0.64 | 0.68 | 0.7 | |
K31 | 0.35 | 0.35 | 0.35 | 0.35 | 0.36 | 0.38 | 0.4 | ||
K33 | 0.68 | 0.7 | 0.68 | 0.7 | 0.7 | 0.76 | 0.77 | ||
Kt | 0.5 | 0.52 | 0.5 | 0.5 | 0.5 | 0.52 | 0.53 | ||
Piezoelectric coefficient | d31 | 10-12m/v | -170 | -197 | -186 | -204 | -227 | -275 | -300 |
d33 | 10-12m/v | 400 | 450 | 500 | 520 | 550 | 620 | 750 | |
g31 | 10-3vm/n | -12 | -11.1 | -9.6 | -9.8 | -9.9 | -9.7 | -7.5 | |
g33 | 10-3vm/n | 28 | 25.4 | 25.6 | 24.5 | 23.9 | 22 | 18.8 | |
Frequency coefficients | Np | 2000 | 1920 | 1980 | 1980 | 1960 | 1900 | 1960 | |
N1 | 1466 | 1407 | 1451 | 1451 | 1437 | 1393 | 1437 | ||
N3 | 1825 | 1925 | 1900 | 1900 | 1755 | 1550 | 1800 | ||
Nt | 2100 | 2100 | 2150 | 2150 | 2150 | 2100 | 2200 | ||
Elastic compliance coefficient | Se11 | 10-12m2/n | 16.6 | 18 | 16.7 | 17 | 17.4 | 18 | 19 |
Machanical quality factor | Qm | 85 | 80 | 80 | 75 | 75 | 70 | 65 | |
Dielectric loss factor | Tg δ | % | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Density | ρ | g/cm3 | 7.5 | 7.5 | 7.6 | 7.6 | 7.6 | 7.5 | 7.5 |
Curie Temperature | Tc | °C | 350 | 345 | 270 | 270 | 270 | 230 | 165 |
Young's modulus | YE11 | <109N/m2 | 60 | 56 | 60 | 59 | 57.5 | 56 | 53 |
Poison Ratio | 0.36 | 0.36 | 0.36 | 0.36 | 0.36 | 0.36 | 0.39 |
PZT Hard Material:
Hard" PZT materials | PZT-41 | PZT-42 | PZT-43/4D | PZT-82 | PBaS-4 | ||
Dielectric Constant | ɛTr3 | 1050 | 1250 | 1420 | 1100 | 1900 | |
Coupling factor | KP | 0.58 | 0.58 | 0.58 | 0.52 | 0.59 | |
K31 | 0.32 | 0.33 | 0.34 | 0.3 | 0.34 | ||
K33 | 0.66 | 0.67 | 0.68 | 0.57 | 0.68 | ||
Kt | 0.48 | 0.48 | 0.48 | 0.4 | 0.49 | ||
Piezoelectric coefficient | d31 | 10-12m/v | -106 | -124 | -138 | -100 | -160 |
d33 | 10-12m/v | 260 | 280 | 300 | 240 | 380 | |
g31 | 10-3vm/n | -11.4 | -11.2 | -11 | -10.3 | -9.5 | |
g33 | 10-3vm/n | 28 | 25.3 | 24 | 25 | 22.6 | |
Frequency coefficients | Np | 2280 | 2200 | 2160 | 2280 | 2200 | |
N1 | 1671 | 1613 | 1583 | 1671 | 1613 | ||
N3 | 1950 | 1900 | 1875 | 1950 | 1850 | ||
Nt | 2250 | 2200 | 2200 | 2300 | 2200 | ||
Elastic compliance coefficient | Se11 | 10-12m2/n | 11.8 | 12.7 | 13.2 | 11.6 | 13.2 |
Machanical quality factor | Qm | 1000 | 800 | 600 | 1200 | 2200 | |
Dielectric loss factor | Tg δ | % | 0.3 | 0.4 | 0.5 | 0.3 | 0.5 |
Density | ρ | g/cm3 | 7.5 | 7.5 | 7.5 | 7.6 | 7.5 |
Curie Temperature | Tc | °C | 320 | 320 | 320 | 310 | 310 |
Young's modulus | YE11 | <109N/m3 | 85 | 79 | 76 | 86 | 76 |
Poison Ratio | 0.3 | 0.3 | 0.3 | 0.3 | 0.33 |
FAQ:
1.About piezoelectric ceramics material , what's the equivalent ceramic materials?
PZT Material Supplier | Navy Type I (PZT-4) | Navy Type II (PZT-5A) | Navy Type VI (PZT-5H) | Navy Type III (PZT-8) |
Piezo Hannas | P-41 | P-51 | P-5H | P-82 |
Morgan Matroc | PZT-4 | PZT-5A | PZT-5H | PZT-8 |
Channel Ind. | C5400 | C5500 | C5700 | C5800 |
EDO Corp. | EC-64 | EC-65 | EC-76 | EC-69 |
Keramos | K-270 | K-350 | K-278 | |
Transducer Products | LTZ-1 | LTZ-2 | LTZ-2H | |
Staveley Sensors | EBL1 | EBL2 | EBL3 | EBL4 |
Medical Diagnostic Application :
Medical diagnostic equipment is used to detect and diagnose medical conditions. The most common type of medical diagnostic equipment is a stethoscope, which is used to listen to internal body sounds. Other examples include blood pressure monitors, pulse oximeters, electrocardiographs (ECGs), electroencephalography (EEGs), ultrasonography (US), and X-ray machines.
Diagnostic equipment is a form of medical equipment used to diagnose health conditions. Diagnostic devices can be simple, such as an otoscope for examining ears, or complicated, such as magnetic resonance imaging (MRI) machines. Diagnostic devices are used to detect and monitor diseases and assess the severity of injury or illness. Diagnostic equipment includes a wide range of medical instruments used in clinical care.
Ultrasonic Medical Focusing Spherical Piezo for Diagnostic Equipment
WuHan Piezohannas Tech.Co .,Ltd is a manufactuer of piezoelectric ceramics ,ultrasonic transducers with strong technology force.With a quality management system and research & development sector,our products are extensively used in most applications.
Working Frequency : 1 ~ 10 MHz (Selectable)
Aperture size : Diameter 20 ~ 70mm(Selectable)
Focal length: 10 ~ 100 mm (Selelctable)
Strong Electrode: Silvering ,Nickel, Titanium Alloys
Long Lifetime: high power pulses>15000
PZT Soft Material:
"Soft" PZT materials | The type of soft material | ||||||||
Properties | PSnN-5 | PLiS-51 | PZT-51 | PZT-52 | PZT-53 | PZT-5H | PZT-5X | ||
Dielectric Constant | ɛTr3 | 1600 | 2000 | 2200 | 2400 | 2600 | 3200 | 4500 | |
Coupling factor | KP | 0.6 | 0.62 | 0.62 | 0.63 | 0.64 | 0.68 | 0.7 | |
K31 | 0.35 | 0.35 | 0.35 | 0.35 | 0.36 | 0.38 | 0.4 | ||
K33 | 0.68 | 0.7 | 0.68 | 0.7 | 0.7 | 0.76 | 0.77 | ||
Kt | 0.5 | 0.52 | 0.5 | 0.5 | 0.5 | 0.52 | 0.53 | ||
Piezoelectric coefficient | d31 | 10-12m/v | -170 | -197 | -186 | -204 | -227 | -275 | -300 |
d33 | 10-12m/v | 400 | 450 | 500 | 520 | 550 | 620 | 750 | |
g31 | 10-3vm/n | -12 | -11.1 | -9.6 | -9.8 | -9.9 | -9.7 | -7.5 | |
g33 | 10-3vm/n | 28 | 25.4 | 25.6 | 24.5 | 23.9 | 22 | 18.8 | |
Frequency coefficients | Np | 2000 | 1920 | 1980 | 1980 | 1960 | 1900 | 1960 | |
N1 | 1466 | 1407 | 1451 | 1451 | 1437 | 1393 | 1437 | ||
N3 | 1825 | 1925 | 1900 | 1900 | 1755 | 1550 | 1800 | ||
Nt | 2100 | 2100 | 2150 | 2150 | 2150 | 2100 | 2200 | ||
Elastic compliance coefficient | Se11 | 10-12m2/n | 16.6 | 18 | 16.7 | 17 | 17.4 | 18 | 19 |
Machanical quality factor | Qm | 85 | 80 | 80 | 75 | 75 | 70 | 65 | |
Dielectric loss factor | Tg δ | % | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Density | ρ | g/cm3 | 7.5 | 7.5 | 7.6 | 7.6 | 7.6 | 7.5 | 7.5 |
Curie Temperature | Tc | °C | 350 | 345 | 270 | 270 | 270 | 230 | 165 |
Young's modulus | YE11 | <109N/m2 | 60 | 56 | 60 | 59 | 57.5 | 56 | 53 |
Poison Ratio | 0.36 | 0.36 | 0.36 | 0.36 | 0.36 | 0.36 | 0.39 |
PZT Hard Material:
Hard" PZT materials | PZT-41 | PZT-42 | PZT-43/4D | PZT-82 | PBaS-4 | ||
Dielectric Constant | ɛTr3 | 1050 | 1250 | 1420 | 1100 | 1900 | |
Coupling factor | KP | 0.58 | 0.58 | 0.58 | 0.52 | 0.59 | |
K31 | 0.32 | 0.33 | 0.34 | 0.3 | 0.34 | ||
K33 | 0.66 | 0.67 | 0.68 | 0.57 | 0.68 | ||
Kt | 0.48 | 0.48 | 0.48 | 0.4 | 0.49 | ||
Piezoelectric coefficient | d31 | 10-12m/v | -106 | -124 | -138 | -100 | -160 |
d33 | 10-12m/v | 260 | 280 | 300 | 240 | 380 | |
g31 | 10-3vm/n | -11.4 | -11.2 | -11 | -10.3 | -9.5 | |
g33 | 10-3vm/n | 28 | 25.3 | 24 | 25 | 22.6 | |
Frequency coefficients | Np | 2280 | 2200 | 2160 | 2280 | 2200 | |
N1 | 1671 | 1613 | 1583 | 1671 | 1613 | ||
N3 | 1950 | 1900 | 1875 | 1950 | 1850 | ||
Nt | 2250 | 2200 | 2200 | 2300 | 2200 | ||
Elastic compliance coefficient | Se11 | 10-12m2/n | 11.8 | 12.7 | 13.2 | 11.6 | 13.2 |
Machanical quality factor | Qm | 1000 | 800 | 600 | 1200 | 2200 | |
Dielectric loss factor | Tg δ | % | 0.3 | 0.4 | 0.5 | 0.3 | 0.5 |
Density | ρ | g/cm3 | 7.5 | 7.5 | 7.5 | 7.6 | 7.5 |
Curie Temperature | Tc | °C | 320 | 320 | 320 | 310 | 310 |
Young's modulus | YE11 | <109N/m3 | 85 | 79 | 76 | 86 | 76 |
Poison Ratio | 0.3 | 0.3 | 0.3 | 0.3 | 0.33 |
FAQ:
1.About piezoelectric ceramics material , what's the equivalent ceramic materials?
PZT Material Supplier | Navy Type I (PZT-4) | Navy Type II (PZT-5A) | Navy Type VI (PZT-5H) | Navy Type III (PZT-8) |
Piezo Hannas | P-41 | P-51 | P-5H | P-82 |
Morgan Matroc | PZT-4 | PZT-5A | PZT-5H | PZT-8 |
Channel Ind. | C5400 | C5500 | C5700 | C5800 |
EDO Corp. | EC-64 | EC-65 | EC-76 | EC-69 |
Keramos | K-270 | K-350 | K-278 | |
Transducer Products | LTZ-1 | LTZ-2 | LTZ-2H | |
Staveley Sensors | EBL1 | EBL2 | EBL3 | EBL4 |
Medical Diagnostic Application :
Medical diagnostic equipment is used to detect and diagnose medical conditions. The most common type of medical diagnostic equipment is a stethoscope, which is used to listen to internal body sounds. Other examples include blood pressure monitors, pulse oximeters, electrocardiographs (ECGs), electroencephalography (EEGs), ultrasonography (US), and X-ray machines.
Diagnostic equipment is a form of medical equipment used to diagnose health conditions. Diagnostic devices can be simple, such as an otoscope for examining ears, or complicated, such as magnetic resonance imaging (MRI) machines. Diagnostic devices are used to detect and monitor diseases and assess the severity of injury or illness. Diagnostic equipment includes a wide range of medical instruments used in clinical care.
Products | About Us | News | Markets and Applications | FAQ | Contact Us