Availability: | |
---|---|
Quantity: | |
PH2110B
Piezohannas
PH2110B
2MHz Ultrasonic Flowmeter Transducer for Ultrasonic Sensor
Technical parameters:
Model | PH2110B |
Centre working frequency (kHz) | 2.00MHZ±4% |
Bandwidth (-6dB) | 10% |
Integrated sensitivity 0 dB=3 Vp-p;cycle:5;distance:8cm | >0.2V |
Measuring Distance: | 1.0M |
Blind zone | 3cm |
Beam angle(-3dBfull angle) | 3° |
electrostatic capacity | 2300PF±20% |
Minimal parallel impedance | 100Ω±30% |
Maxim operating voltage impulse wave(Pulse Duty cycle ratio 2%) | <200V |
Operating temperature | 4~50℃ |
The material of the housing | PPS |
Protection class | IP68 |
The above tests were conducted in 25 °environment.
Image:
Outline Dimension:
Admittance - phase curve
Sensitivity test
Transmitting voltage: 3Vp-p;
period: 5; distance: 8cm
Ultrasonic Water Flowmeter Application:
An ultrasonic flow meter utilizes ultrasound to measure the velocity of a fluid and is used in a variety of fluid applications. Ultrasonic flowmeters are ideal for water and other liquids. Clamp-on ultrasonic flow meters achieve high accuracy at low and high flows, save time with no pipe cutting or process shutdown, and are not affected by external noise.
2MHz Ultrasonic Flowmeter Transducer for Ultrasonic Sensor
Technical parameters:
Model | PH2110B |
Centre working frequency (kHz) | 2.00MHZ±4% |
Bandwidth (-6dB) | 10% |
Integrated sensitivity 0 dB=3 Vp-p;cycle:5;distance:8cm | >0.2V |
Measuring Distance: | 1.0M |
Blind zone | 3cm |
Beam angle(-3dBfull angle) | 3° |
electrostatic capacity | 2300PF±20% |
Minimal parallel impedance | 100Ω±30% |
Maxim operating voltage impulse wave(Pulse Duty cycle ratio 2%) | <200V |
Operating temperature | 4~50℃ |
The material of the housing | PPS |
Protection class | IP68 |
The above tests were conducted in 25 °environment.
Image:
Outline Dimension:
Admittance - phase curve
Sensitivity test
Transmitting voltage: 3Vp-p;
period: 5; distance: 8cm
Ultrasonic Water Flowmeter Application:
An ultrasonic flow meter utilizes ultrasound to measure the velocity of a fluid and is used in a variety of fluid applications. Ultrasonic flowmeters are ideal for water and other liquids. Clamp-on ultrasonic flow meters achieve high accuracy at low and high flows, save time with no pipe cutting or process shutdown, and are not affected by external noise.
Products | About Us | News | Markets and Applications | FAQ | Contact Us