Availability: | |
---|---|
Quantity: | |
PHA-200-01K
Piezohannas
PHA-200-01K
200KHz Ultrasonic Transducer Wind Speed Sensor for Ultrasonic Anemometer Sensor
Items | Technical Parameters | Image | |
Name | 200KHz ultrasonic transducer |
| |
Model | PHA-200-01K | ||
Frequency | 200KHz±5% | ||
Detection Distance | 0.10~1.5m | ||
Minimum Parallel lmpedance | 2300Ω±20% | ||
370pF±20% @1KHz | |||
Sensitivity | Driving Voltage:800Vpp,Distance0.3m, Echo Amplitude25mV | ||
-40~+80℃ | |||
≤3Kilos or 0.3MPa | |||
| (Beamwidth) Half-power Beam Width@-3dB:10°±2, Sharp Angle:23°±4 | ||
Housing Material | POM | ||
Usage | anemorumbometer,gas flowmeter | ||
thread:M12*1.5 | |||
Protection Level | IP68 | ||
Weight | 10g±5%(length:10cm) | ||
Wiring Instructions | integrated type:Red+,White-,Black: shielded wire(default: without temperature sensor) | ||
Admittance Curve | Product Structure Diagram | ||
|
|
Block diagram of ultrasonic transducer :
Schematic Diagram of Temperature Sensor:
Integrated type Cable instruction: :
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +
White: transducer -
Black: shielding
2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)
Red and black are temperature sensor wiring
Application for Ultrasonic Wind Sensor:
anemometers work on the principle that the travel time of sound waves through air is affected by the wind speed component parallel with the direction of travel. The basic element of a sonic anemometer consists of an ultrasonic sound emitter and receiver at opposite ends of a sampling volume.It works by the rotation of the arrow of the wind direction, and transmits it to the coaxial code plate, at the same time outputs the relevant values of the wind direction. Usually the main body of the wind direction sensor adopts the mechanical structure of the wind vane.
Image for Ultrasonic Anemometer Sensor:
200KHz Ultrasonic Transducer Wind Speed Sensor for Ultrasonic Anemometer Sensor
Items | Technical Parameters | Image | |
Name | 200KHz ultrasonic transducer |
| |
Model | PHA-200-01K | ||
Frequency | 200KHz±5% | ||
Detection Distance | 0.10~1.5m | ||
Minimum Parallel lmpedance | 2300Ω±20% | ||
370pF±20% @1KHz | |||
Sensitivity | Driving Voltage:800Vpp,Distance0.3m, Echo Amplitude25mV | ||
-40~+80℃ | |||
≤3Kilos or 0.3MPa | |||
| (Beamwidth) Half-power Beam Width@-3dB:10°±2, Sharp Angle:23°±4 | ||
Housing Material | POM | ||
Usage | anemorumbometer,gas flowmeter | ||
thread:M12*1.5 | |||
Protection Level | IP68 | ||
Weight | 10g±5%(length:10cm) | ||
Wiring Instructions | integrated type:Red+,White-,Black: shielded wire(default: without temperature sensor) | ||
Admittance Curve | Product Structure Diagram | ||
|
|
Block diagram of ultrasonic transducer :
Schematic Diagram of Temperature Sensor:
Integrated type Cable instruction: :
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +
White: transducer -
Black: shielding
2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)
Red and black are temperature sensor wiring
Application for Ultrasonic Wind Sensor:
anemometers work on the principle that the travel time of sound waves through air is affected by the wind speed component parallel with the direction of travel. The basic element of a sonic anemometer consists of an ultrasonic sound emitter and receiver at opposite ends of a sampling volume.It works by the rotation of the arrow of the wind direction, and transmits it to the coaxial code plate, at the same time outputs the relevant values of the wind direction. Usually the main body of the wind direction sensor adopts the mechanical structure of the wind vane.
Image for Ultrasonic Anemometer Sensor:
Products | About Us | News | Markets and Applications | FAQ | Contact Us