Hubei Hannas Tech Co.,Ltd-Professional Piezoceramic Elements Supplier
News
You are here: Home / News / Ultrasonic Transducer information / troubleshooting one of Ultrasonic dishwasher vibrator

troubleshooting one of Ultrasonic dishwasher vibrator

Views: 12     Author: Site Editor     Publish Time: 2019-04-24      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Q:  whatultrasonic cleaning effect is slow?


Answer: 1. The cleaning liquid level in the cleaning tank is improper, and the water level is adjusted, generally 2-3 cm.
2. The temperature of the liquid in the cleaning tank is too high or too low.
3. Whether the cleaning solution is changed, whether the concentration of the cleaning solution is low or not, and the concentration is increased.
4. Open the case and observe if the ultrasonic transducer is disconnected. For temporary processing, the transducer can be skipped for connection.
The benefits of washing the dishwasher with ultrasonic vibrators:
The cleaning method of piezoelectric ultrasonic cleaning transducer has no dead angle for the cleaning of the product or the appliance, and the stain liquid in the groove can be cleaned, and the cleaning cleanliness is very high.

Fault Solution of Ultrasonic Dishwasher


Q: Does the ultrasonic dishwasher start up not working?


A: The ultrasonic dishwasher turns on the power switch and there is no ultrasonic output.


1. No power is connected;
2. The power switch or power output line is damaged, there is no power input;
3. The power adjustment button is at the zero position, and the knob is adjusted to a current of 4A;
4. The fuse is blown, check if the power supply is wrongly connected to 380V, and then replace the fuse;
5. Check if the protection light on the protection circuit board is lit. If it is lit, the ultrasonic power supply of Industrial ultrasonic cleaning is in the protection state. Turn off the power for 1 minute and then restart. If this still happens, adjust the protection on the protection circuit board. Potentiometer counterclockwise turn 5-10 degrees (this operation is to enlarge the protection)


Feedback
Hubei Hannas Tech Co.,Ltd  is a professional piezoelectric ceramics and ultrasonic transducer manufacturer, dedicated to ultrasonic technology and industrial applications.                                    
 

RECOMMEND

CONTACT US

Add: No.302 Innovation Agglomeration Zone, Chibi Avenu ,Chibi City, Xianning, Hubei Province,China
E-mail: sales@piezohannas.com
Tel: +86 07155272177
Phone: +86 +18986196674         
QQ: 1553242848 
Skype: live:mary_14398
​        
Copyright 2017  Hubei Hannas Tech Co.,Ltd All rights reserved. 
Products