PHA-200-01VF
Piezohannas
PHA-200-01VF
Stainless Steel 200KHz Ultrasonic Transducer for Ultrasonic Gas Flowmeter
Items | Technical Parameters | Image | |
Name | 200KHz ultrasonic transducer |
| |
Model | PHA-200-01VF | ||
Frequency | 200KHz±5% | ||
Detection Distance | 0.10~1.5m | ||
Minimum Parallel lmpedance | 1720Ω±20% | ||
450pF±20% @1KHz | |||
Sensitivity | Driving Voltage:800Vpp,Distance:0.3m, Echo Amplitude:40mV | ||
-40~+80℃ | |||
≤1Kilos or 0.1MPa | |||
| (Beamwidth) Half-power Beam Width@-3dB:7°±2, Sharp Angle:16°±4 | ||
Housing Material | stainless steel | ||
Usage | anemorumbometer,gas flowmeter | ||
See the structure diagram below | |||
Protection Level | IP68 | ||
Weight | 14g±5%(length:25cm) | ||
Wiring Instructions | integrated type:Red+,White-,Black: shielded wire;Temperature Sensor is optional
| ||
Admittance Curve | Product Structure Diagram | ||
|
|
Test circuit schematic diagram of ultrasonic transducer:
Schematic Diagram of Temperature Sensor:
Echo test diagram of transducer
test environment is 0.6 meters and the test point is ECHO×1
Admittance curve of the transducer:
Integrated type Cable instruction:
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +
White: transducer -
Black: shielding
Stainless Steel 200KHz Ultrasonic Transducer for Ultrasonic Gas Flowmeter
Items | Technical Parameters | Image | |
Name | 200KHz ultrasonic transducer |
| |
Model | PHA-200-01VF | ||
Frequency | 200KHz±5% | ||
Detection Distance | 0.10~1.5m | ||
Minimum Parallel lmpedance | 1720Ω±20% | ||
450pF±20% @1KHz | |||
Sensitivity | Driving Voltage:800Vpp,Distance:0.3m, Echo Amplitude:40mV | ||
-40~+80℃ | |||
≤1Kilos or 0.1MPa | |||
| (Beamwidth) Half-power Beam Width@-3dB:7°±2, Sharp Angle:16°±4 | ||
Housing Material | stainless steel | ||
Usage | anemorumbometer,gas flowmeter | ||
See the structure diagram below | |||
Protection Level | IP68 | ||
Weight | 14g±5%(length:25cm) | ||
Wiring Instructions | integrated type:Red+,White-,Black: shielded wire;Temperature Sensor is optional
| ||
Admittance Curve | Product Structure Diagram | ||
|
|
Test circuit schematic diagram of ultrasonic transducer:
Schematic Diagram of Temperature Sensor:
Echo test diagram of transducer
test environment is 0.6 meters and the test point is ECHO×1
Admittance curve of the transducer:
Integrated type Cable instruction:
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +
White: transducer -
Black: shielding