Preparation tools of of ultrasonic cleaning transducer:
Argon arc welding, hex wrench No. 10, ferrochrome wire, 2.5 square high temperature wire, 2*2.5 cable wire, vibrator glue, (stripping pliers, casing, cable ties, sand blasting machine, pipe fittings, etc..
Welding screws: Calculate the position of the vibrator, weld the screws in the cleaned position, and then clean the screws around, vibration cleaning transducer is sure to make them flat, so as not to affect the vibrator installation.
Glue configuration: Stir the glue evenly in the specified proportion. (Merray, Araldite, 4030 glue mixed before bonding, KMD398 glue mixed in the bonding process).
Install the vibrating head: Spread the glue evenly on the bottom of the piezoelectric cleaning transducer, and gently squeeze the air and excess glue between the bottom of the transducer and the bottom contact surface to make the vibrator more tightly integrated with the stainless steel.
Curing and solidification: solidified at a relatively high room temperature, 4-8 hours can be connected, 24 hours after the power can be tested, the test machine is absolutely not allowed to air vibration.