| Ketersediaan | |
|---|---|
| Kuantiti: | |
8103
Piezohannas
8103
20Hz-180kHz Kepekaan Tinggi Transduser Hidrofon Kecil

Parameter Teknikal:
1. Butiran Pengukuran:
1.1. Menerima Sensitiviti
Ukur sensitiviti penerima transduser hidrofon dalam jalur frekuensi 20 Hz hingga 180 kHz. Kepekaan dari 20 Hz hingga 100 kHz hendaklah tidak kurang daripada -211 dB.
1.2. Tekanan Hidrostatik: 5 MPa.
2. Data Pengukuran
2.1. Menerima Sensitiviti
f/kHz |
Mx/dB |
f/kHz |
Mx/dB |
0.02 |
-205.9 |
5 |
-207.5 |
0.025 |
-205.9 |
6.3 |
-207.7 |
0.0315 |
-206.1 |
8 |
-208.1 |
0.04 |
-206.0 |
10 |
-208.5 |
0.063 |
-206.1 |
12.5 |
-208.8 |
0.08 |
-206.2 |
16 |
-208.9 |
0.1 |
-206.3 |
20 |
-207.7 |
0.125 |
-206.5 |
25 |
-206.5 |
0.16 |
-206.5 |
31.5 |
-205.7 |
0.2 |
-206.1 |
40 |
-207.7 |
0.25 |
-206.2 |
50 |
-209.9 |
0.315 |
-206.2 |
63 |
-211.6 |
0.4 |
-206.2 |
80 |
-208.6 |
0.5 |
-206.5 |
100 |
-206.1 |
0.63 |
-206.1 |
125 |
-206.0 |
0.8 |
-206.3 |
130 |
-204.4 |
1 |
-206.2 |
140 |
-200.9 |
1.25 |
-206.2 |
144 |
-201.7 |
1.6 |
-206.4 |
150 |
-201.4 |
2 |
-206.2 |
160 |
-202.9 |
2.5 |
-206.5 |
180 |
-205.8 |
3.15 |
-206.9 |
200 |
-211.5 |
4 |
-207.2 |
sensitifKeluk

C0 |
1.37nF |
Ujian Tekanan Hidrostatik
Selepas menjalani ujian tekanan hidrostatik pada 5MPa/1j, 0MPa/0.25j, dan 5MPa/1j, rintangan penebat antara elektrod positif dan negatif hidrofon adalah lebih besar daripada 100MΩ.
Keputusan Pengukuran:
Prestasi hidrofon memenuhi keperluan .
.