40Khz Long Range Ultrasonic Sensor for Liquid Level Measurement
Product Description
40Khz Long Range Ultrasonic Sensor for Liquid Level Measurement
Applications:
Surface -mount ,Range of up to 4m enables reliable long-range detection.
Suitable for distance,liquid level,level measurement ,perception,anti-collision field high protection level can be used outdoors.
Parameters:
Ultrasonic sensor |
Technical data |
General Specifications |
|
Sensing distance |
400…10000mm |
Adjustment range |
400…10000mm |
Unusable area |
0…400mm |
Standard target plate |
100mm×100mm |
Transducer frequency About |
40 kHz |
Response delay About |
150ms |
Indicators/Operating means |
|
LED yellow |
solid: NO LED |
LED red |
flashing: |
Electrical specifications |
|
Operating voltage UB |
10…30VDC ripple10%ss 13…30VDC(Analog output 0-10V) |
No-load supply current |
≤30mA |
Output |
|
Output type |
1 analogue output 4---20mA |
Resolution |
|
Deviation of the characteristic |
±1% of full-scale value |
Repeat accuracy |
±0.1% of full-scale value |
Load impedance |
>1k Ohm |
Maximum switching current |
200 mA |
Temperature influence |
±1.5% of full-scale value |
Ambient conditions |
|
Ambient temperature |
-25…70℃ |
Storage temperature |
-40…85℃ |
Mechanical specifications |
|
Protection grade |
IP68 |
Connection |
PVC cable,4-cables |
Material |
|
Housing |
PBT OR FRP |
Transducer |
epoxy resin/hollow glass sphere |
Weight |
280g |
Compliance with standards and Directives |
|
Standard conformity |
EN 60947-5-2:2007 |
Dimension:
Adjusting the evaluation limits
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s.
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with -UB, A2 with +UB.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
Evaluation limits may only be specified within the first 5 minutes after
Power on. To modify the evaluation limits later,
the user may specify the desired values only after a new Power On.
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + UB
TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with - UB
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp
LED Displays (SR80 series no led)
Displays in dependence on operating mode |
Red LED |
Blue LED |
TEACH-IN evaluation limit Object detected No object detected Object uncertain (TEACH-IN invalid) |
off off flashes |
On off off |
Normal mode (evaluation range) |
off |
on |
Fault |
on |
previous state |