Industrial Non Contact Ultrasonic Sensor for Distance Measurement

Product Description

Industrial Non Contact Ultrasonic Sensor for Distance Measurement


Parameters:


Technical data

General Specifications

Sensing distance         100…1000mm(50…800mm)

Adjustment range    100…1000mm(50…800mm)

Unusable area     0…100mm(0…50mm)

Standard target plate   100mm×100mm

Transducer frequency   About 200 kHz

Response delay    About 125ms

Indicators/Operating means

LED  yellow                solid: object in evaluation range

                           flashing: program function

LED  red           flashing: fault or program function object not detected


Electrical specifications

Operating voltage UB   10…30VDC,ripple10%ss

No-load supply current   ≤20mA

Output

Output type            1 analogue output 0…10V

Resolution     0.11mm at max.sensing range

Deviation of the characteristic

curve                     ±1% of full-scale value

Repeat accuracy               ±0.1% of full-scale value

Load impedance          >1k Ohm

Temperature influence   ±1.5% of full-scale value

Ambient conditions

Ambient temperature         -25…70℃

Storage temperature   -40…85℃

Mechanical specifications

Protection grade    IP67

Connection        Connector M12x1,4-PIN

Material

   Housing        brass,nickel-plated

Transducer                   epoxy resin/hollow glass sphere mixture;

                            Polyurethane foam

Weight         60g





Dimension:



Adjusting the evaluation limits

The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply

voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs

indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught

with -UB, A2 with +UB.

Two different output functions can be set:

1. Analogue value increases with rising distance to object (rising ramp)

2. Analogue value falls with rising distance to object (falling ramp)

Evaluation limits may only be specified within the first 5 minutes after

Power on. To modify the evaluation limits later,

the user may specify the desired values only after a new Power On.

 

TEACH-IN rising ramp (A2 > A1)

- Position object at lower evaluation limit

- TEACH-IN lower limit A1 with - UB

- Position object at upper evaluation limit                                                

- TEACH-IN upper limit A2 with + UB

 

TEACH-IN falling ramp (A1 > A2):

- Position object at lower evaluation limit                                              

- TEACH-IN lower limit A2 with + UB                                                    

- Position object at upper evaluation limit

- TEACH-IN upper limit A1 with - UB                                                                   

 

Default setting

A1: unusable area

A2: nominal sensing range

Mode of operation: rising ramp    






LED Displays

Displays in dependence on operating mode

Red LED

Yellow LED

TEACH-IN evaluation limit

Object detected

No object detected

Object uncertain (TEACH-IN invalid)

 

off

flashes

on

 

flashes

off

off

Normal mode (evaluation range)

off

on

Fault

on

previous state


Feedback