20Hz-200kHz Sferiese Kommunikasie Transducer vir Onderwater Sonar

Meting inhoud:
Werkende frekwensieband
Die werkfrekwensieband van die hidrofoon is 20Hz-200kHz.
Ontvang sensitiwiteit
Meet die ontvangsensitiwiteit binne die werkfrekwensieband van die hidrofoon.
Stuur reaksie
Meet die uitstuurreaksie van die hidrofoon, meet frekwensie 100kHz-200kHz (interval 5kHz).
Horisontale rigting
Omnirigting, meetfrekwensie 50kHz, 100kHz.
Hidrostatiese drukweerstand
Die hidrofoon moet 2Mpa hidrostatiese druktoets kan weerstaan.
Toelatingsparameters

202401# |
202402# |
||||
f/kHz |
G/ms |
B/ms |
f/kHz |
G/ms |
B/ms |
100 |
0.07 |
1.94 |
100 |
0.09 |
1.94 |
105 |
0.13 |
2.08 |
105 |
0.16 |
2.07 |
110 |
0.19 |
2.18 |
110 |
0.22 |
2.19 |
115 |
0.20 |
2.33 |
115 |
0.28 |
2.35 |
120 |
0.28 |
2.57 |
120 |
0.39 |
2.55 |
125 |
0.47 |
2.80 |
125 |
0.59 |
2.75 |
130 |
0.76 |
3.00 |
130 |
0.91 |
2.88 |
135 |
1.19 |
3.06 |
135 |
1.29 |
2.81 |
140 |
1.44 |
2.84 |
140 |
1.43 |
2.69 |
145 |
1.71 |
2.93 |
145 |
1.72 |
2.63 |
150 |
2.21 |
2.63 |
150 |
2.00 |
2.36 |
155 |
2.42 |
2.07 |
155 |
2.17 |
1.92 |
160 |
2.30 |
1.43 |
160 |
1.98 |
1.40 |
165 |
1.84 |
1.05 |
165 |
1.58 |
1.16 |
170 |
1.35 |
0.98 |
170 |
1.20 |
1.14 |
175 |
0.97 |
1.11 |
175 |
0.90 |
1.28 |
180 |
0.82 |
1.35 |
180 |
0.81 |
1.45 |
185 |
0.74 |
1.39 |
185 |
0.71 |
1.55 |
190 |
0.63 |
1.55 |
190 |
0.70 |
1.62 |
195 |
0.58 |
1.48 |
195 |
0.56 |
1.63 |
200 |
0.31 |
1.59 |
200 |
0.45 |
1.78 |
Sensitiwiteit ontvang
2024-01# |
|||
f/kHz |
Mx/dB |
f/kHz |
Mx/dB |
0.02 |
-204.4 |
2.5 |
-204.4 |
0.025 |
-204.3 |
3.15 |
-204.6 |
0.0315 |
-204.1 |
4 |
-204.4 |
0.04 |
-203.7 |
5 |
-204.6 |
0.063 |
-203.8 |
6.3 |
-204.4 |
0.08 |
-203.4 |
8 |
-204.9 |
0.1 |
-204.0 |
10 |
-204.8 |
0.125 |
-203.4 |
12.5 |
-204.9 |
0.16 |
-204.0 |
16 |
-205.0 |
0.2 |
-203.9 |
20 |
-205.0 |
0.25 |
-204.5 |
25 |
-204.9 |
0.315 |
-203.9 |
31.5 |
-204.8 |
0.4 |
-203.9 |
40 |
-205.0 |
0.5 |
-204.2 |
50 |
-204.9 |
0.63 |
-204.1 |
63 |
-204.8 |
0.8 |
-204.2 |
80 |
-205.0 |
1 |
-204.0 |
100 |
-204.9 |
1.25 |
-203.7 |
125 |
-205.0 |
1.6 |
-204.1 |
160 |
-203.1 |
2 |
-204.3 |
200 |
-204.3 |
2024-02# |
|||
f/kHz |
Mx/dB |
f/kHz |
Mx/dB |
0.02 |
-205.0 |
2.5 |
-204.7 |
0.025 |
-204.8 |
3.15 |
-204.9 |
0.0315 |
-204.9 |
4 |
-204.9 |
0.04 |
-204.7 |
5 |
-205.0 |
0.063 |
-205.0 |
6.3 |
-2048 |
0.08 |
-204.7 |
8 |
-204.7 |
0.1 |
-205.0 |
10 |
-204.6 |
0.125 |
-204.9 |
12.5 |
-204.7 |
0.16 |
-204.8 |
16 |
-204.5 |
0.2 |
-204.9 |
20 |
-204.7 |
0.25 |
-204.7 |
25 |
-205.0 |
0.315 |
-204.9 |
31.5 |
-204.9 |
0.4 |
-204.8 |
40 |
-205.0 |
0.5 |
-205.0 |
50 |
-204.6 |
0.63 |
-204.7 |
63 |
-205.0 |
0.8 |
-204.9 |
80 |
-204.9 |
1 |
-204.6 |
100 |
-205.0 |
1.25 |
-204.9 |
125 |
-204.7 |
1.6 |
-204.4 |
160 |
-202.8 |
2 |
-204.4 |
200 |
-205.0 |
f/kHz |
2024-01# |
2024-02# |
SvL/dB |
SvL/dB |
|
100 |
136.2 |
136.5 |
105 |
137.5 |
137.4 |
110 |
138.1 |
139.2 |
115 |
138.8 |
139.5 |
120 |
139.2 |
140.3 |
125 |
140.9 |
140.6 |
130 |
141.7 |
141.3 |
135 |
142.0 |
142.5 |
140 |
142.8 |
143.6 |
145 |
143.6 |
144.1 |
150 |
145.0 |
145.1 |
155 |
145.9 |
146.2 |
160 |
145.6 |
145.1 |
165 |
144.3 |
143.2 |
170 |
143.6 |
142.0 |
175 |
142.9 |
142.6 |
180 |
142.2 |
143.4 |
185 |
141.6 |
142.8 |
190 |
141.3 |
142.6 |
195 |
141.2 |
142.5 |
200 |
140.6 |
141.9 |
Horisontale rigting


Hidrostatiese druk toets
Nadat die hidrofoon aan 2Mpa/1h, 0Mpa/0.25h, 2Mpa/1h, en 0Mpa/0.25h hidrostatiese druktoetse onderwerp is, het die hidrofoon geen skade of abnormaliteit aan die buitekant nie, en die isolasieweerstand tussen die positiewe en negatiewe elektrodes van die hidrofoon is groter as 200 megohms en die positiewe weerstand en die negatiewe elektrodes. meer as 200 megohm.