| Ketersediaan: | |
|---|---|
| Kuantiti: | |
Piezohannas
Transduser Komunikasi Sfera 20Hz-200kHz untuk Sonar Bawah Air

Kandungan Pengukuran:
Jalur frekuensi kerja
Jalur frekuensi kerja hidrofon ialah 20Hz-200kHz.
Menerima sensitiviti
Ukur sensitiviti penerimaan dalam jalur frekuensi kerja hidrofon.
Menghantar respons
Ukur tindak balas penghantaran hidrofon, mengukur frekuensi 100kHz-200kHz (selang 5kHz).
Kearah mendatar
Omnidirectional, mengukur frekuensi 50kHz, 100kHz.
Rintangan tekanan hidrostatik
Hidrofon harus dapat menahan ujian tekanan hidrostatik 2Mpa.
Parameter kemasukan

202401# |
202402# |
||||
f/kHz |
G/ms |
B/ms |
f/kHz |
G/ms |
B/ms |
100 |
0.07 |
1.94 |
100 |
0.09 |
1.94 |
105 |
0.13 |
2.08 |
105 |
0.16 |
2.07 |
110 |
0.19 |
2.18 |
110 |
0.22 |
2.19 |
115 |
0.20 |
2.33 |
115 |
0.28 |
2.35 |
120 |
0.28 |
2.57 |
120 |
0.39 |
2.55 |
125 |
0.47 |
2.80 |
125 |
0.59 |
2.75 |
130 |
0.76 |
3.00 |
130 |
0.91 |
2.88 |
135 |
1.19 |
3.06 |
135 |
1.29 |
2.81 |
140 |
1.44 |
2.84 |
140 |
1.43 |
2.69 |
145 |
1.71 |
2.93 |
145 |
1.72 |
2.63 |
150 |
2.21 |
2.63 |
150 |
2.00 |
2.36 |
155 |
2.42 |
2.07 |
155 |
2.17 |
1.92 |
160 |
2.30 |
1.43 |
160 |
1.98 |
1.40 |
165 |
1.84 |
1.05 |
165 |
1.58 |
1.16 |
170 |
1.35 |
0.98 |
170 |
1.20 |
1.14 |
175 |
0.97 |
1.11 |
175 |
0.90 |
1.28 |
180 |
0.82 |
1.35 |
180 |
0.81 |
1.45 |
185 |
0.74 |
1.39 |
185 |
0.71 |
1.55 |
190 |
0.63 |
1.55 |
190 |
0.70 |
1.62 |
195 |
0.58 |
1.48 |
195 |
0.56 |
1.63 |
200 |
0.31 |
1.59 |
200 |
0.45 |
1.78 |
Menerima Sensitiviti
2024-01# |
|||
f/kHz |
Mx/dB |
f/kHz |
Mx/dB |
0.02 |
-204.4 |
2.5 |
-204.4 |
0.025 |
-204.3 |
3.15 |
-204.6 |
0.0315 |
-204.1 |
4 |
-204.4 |
0.04 |
-203.7 |
5 |
-204.6 |
0.063 |
-203.8 |
6.3 |
-204.4 |
0.08 |
-203.4 |
8 |
-204.9 |
0.1 |
-204.0 |
10 |
-204.8 |
0.125 |
-203.4 |
12.5 |
-204.9 |
0.16 |
-204.0 |
16 |
-205.0 |
0.2 |
-203.9 |
20 |
-205.0 |
0.25 |
-204.5 |
25 |
-204.9 |
0.315 |
-203.9 |
31.5 |
-204.8 |
0.4 |
-203.9 |
40 |
-205.0 |
0.5 |
-204.2 |
50 |
-204.9 |
0.63 |
-204.1 |
63 |
-204.8 |
0.8 |
-204.2 |
80 |
-205.0 |
1 |
-204.0 |
100 |
-204.9 |
1.25 |
-203.7 |
125 |
-205.0 |
1.6 |
-204.1 |
160 |
-203.1 |
2 |
-204.3 |
200 |
-204.3 |
2024-02# |
|||
f/kHz |
Mx/dB |
f/kHz |
Mx/dB |
0.02 |
-205.0 |
2.5 |
-204.7 |
0.025 |
-204.8 |
3.15 |
-204.9 |
0.0315 |
-204.9 |
4 |
-204.9 |
0.04 |
-204.7 |
5 |
-205.0 |
0.063 |
-205.0 |
6.3 |
-2048 |
0.08 |
-204.7 |
8 |
-204.7 |
0.1 |
-205.0 |
10 |
-204.6 |
0.125 |
-204.9 |
12.5 |
-204.7 |
0.16 |
-204.8 |
16 |
-204.5 |
0.2 |
-204.9 |
20 |
-204.7 |
0.25 |
-204.7 |
25 |
-205.0 |
0.315 |
-204.9 |
31.5 |
-204.9 |
0.4 |
-204.8 |
40 |
-205.0 |
0.5 |
-205.0 |
50 |
-204.6 |
0.63 |
-204.7 |
63 |
-205.0 |
0.8 |
-204.9 |
80 |
-204.9 |
1 |
-204.6 |
100 |
-205.0 |
1.25 |
-204.9 |
125 |
-204.7 |
1.6 |
-204.4 |
160 |
-202.8 |
2 |
-204.4 |
200 |
-205.0 |
f/kHz |
2024-01# |
2024-02# |
SvL/dB |
SvL/dB |
|
100 |
136.2 |
136.5 |
105 |
137.5 |
137.4 |
110 |
138.1 |
139.2 |
115 |
138.8 |
139.5 |
120 |
139.2 |
140.3 |
125 |
140.9 |
140.6 |
130 |
141.7 |
141.3 |
135 |
142.0 |
142.5 |
140 |
142.8 |
143.6 |
145 |
143.6 |
144.1 |
150 |
145.0 |
145.1 |
155 |
145.9 |
146.2 |
160 |
145.6 |
145.1 |
165 |
144.3 |
143.2 |
170 |
143.6 |
142.0 |
175 |
142.9 |
142.6 |
180 |
142.2 |
143.4 |
185 |
141.6 |
142.8 |
190 |
141.3 |
142.6 |
195 |
141.2 |
142.5 |
200 |
140.6 |
141.9 |
Kearah mendatar


Ujian tekanan hidrostatik
Selepas hidrofon telah menjalani ujian tekanan hidrostatik 2Mpa/1j, 0Mpa/0.25j, 2Mpa/1j dan 0Mpa/0.25j, hidrofon tidak mempunyai kerosakan atau kelainan di luar, dan rintangan penebat antara elektrod positif dan negatif hidrofon adalah lebih besar daripada 200 megohms dan rintangan negatif antara perisai positif dan negatif. 200 megohm.