power and frequency selection of ultrasonic cleaning transducer
Publish Time: 2019-04-15 Origin: Site
Power selection:
Ultrasonic cleaning transducer is not necessarily proportional to (power × cleaning time), sometimes with low power, and it takes a long time to remove dirt. And if the power reaches a certain value, the dirt is sometimes removed quickly. If the power is too large, the cavitation intensity will be greatly increased, and the cleaning effect will be improved. However, the more precise parts will also have an etch point, which is not worth the loss, and the cavitation at the bottom of the cleaning cylinder is severe, and the water point corrosion of ultra bath transducer is also increased. When is using organic solvents such as trichloroethylene, there is basically no problem, but when using water or water-soluble cleaning solution, it is easy to be affected by water spots. If the surface of the vibrating plate has been scratched, cavitation corrosion occurs under the high power.so to choose the ultrasound power according to the actual use.
Frequency selection: