105KHz Ultrasonic Transducer Distance for Ultrasonic Level Measurement
Product Description
Low Cost 105KHz Ultrasonic Transducer for Anemorumbometer
Technical parameters:
Items | Technical Parameters | Image | |
Name | 105KHz ultrasonic transducer C type |
| |
Model | PHA-105-03C | ||
Frequency | 105KHz±5% | ||
Detection Distance | 0.15~3m | ||
Minimum Parallel lmpedance | 540Ω±20% | ||
1200pF±20% @1KHz | |||
Sensitivity | Driving Voltage:750Vpp,Distance:0.3m, Echo Amplitude:150mV | ||
-40~+80℃ | |||
≤3Kilos or 0.3MPa | |||
| (Beamwidth) Half-power Beam Width@-3dB:9.1°±2, Sharp Angle:21.7°±4 | ||
Housing Material | LY12 | ||
Usage | Ultrasonic level gauge,ultrasonic transducer,anemorumbometer ,ultrasonic gas flow meter | ||
Check the structure diagram below | |||
Protection Level | IP68 | ||
Weight | 50g±5%(Length:2m) | ||
Wiring Instructions | integrated type:connector:Red+,White-,Black: shielded wire; ( temp sensor is optional) | ||
Admittance Curve | Product Structure Diagram | ||
|
|
Block diagram of ultrasonic transducer :
Schematic Diagram of Temperature Sensor:
Integrated type Cable instruction: :
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +
White: transducer -
Black: shielding
2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)
Red and black are temperature sensor wiring
Application of Ultrasonic level measurement:
Continuous level measurement in liquids and solids with ultrasonic level sensors
Ultrasonic level measurement with Prosonic sensors provides continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of the sensors. Check out the broad range of Prosonic devices for ultrasonic level measurement and click on the button below.