1. Meting inhoud:



Spanningsoordragreaksie en klankbronvlak:
By die resonante frekwensie moet die respons nie minder as 141dB wees nie, die klankbronvlak moet nie minder as 196dB wees nie, en die uitsaairesponsbandwydte moet nie minder nie as 3.5kHz wees.
Ontvanger Sensitiwiteit: Nie minder nie as -189dB by die resonante frekwensie.
Hidrostatiese druk: 7MPa.
Meetdata
Daar is twee transducers, 202501# en 202502#. Die metingsdata is soos volg.
Weerstand en kapasitor parameters
Weerstand en kapasitor parameters


202501# |
||||||
f/kHz |
d/m |
U发/Vpp |
U收/mVpp |
M0/dB |
SvL/dB |
SL/dB |
24 |
0.924 |
800 |
252 |
-217 |
146.3 |
195.3 |
25 |
0.924 |
800 |
290 |
-217 |
147.5 |
196.5 |
26 |
0.924 |
800 |
310 |
-217 |
148.1 |
197.1 |
27 |
0.924 |
800 |
330 |
-217 |
148.6 |
197.6 |
28 |
0.924 |
800 |
344 |
-217 |
149.0 |
198.0 |
29 |
0.924 |
800 |
344 |
-217 |
149.0 |
198.0 |
30 |
0.924 |
800 |
332 |
-217 |
148.7 |
197.7 |
31 |
0.924 |
800 |
316 |
-217 |
148.2 |
197.3 |
32 |
0.924 |
800 |
284 |
-217 |
147.3 |
196.3 |
202502# |
||||||
f/kHz |
d/m |
U发/Vpp |
U收/mVpp |
M0/dB |
SvL/dB |
SL/dB |
24 |
0.924 |
796 |
202 |
-217 |
144.4 |
193.4 |
25 |
0.924 |
796 |
232 |
-217 |
145.6 |
194.6 |
26 |
0.924 |
796 |
248 |
-217 |
146.2 |
195.2 |
27 |
0.924 |
796 |
259 |
-217 |
146.6 |
195.5 |
28 |
0.924 |
796 |
280 |
-217 |
147.2 |
196.2 |
29 |
0.924 |
796 |
285 |
-217 |
147.4 |
196.4 |
30 |
0.924 |
796 |
277 |
-217 |
147.1 |
196.1 |
31 |
0.924 |
796 |
262 |
-217 |
146.7 |
195.6 |
32 |
0.924 |
796 |
240 |
-217 |
145.9 |
194.9 |
f/kHz |
202401# |
202402# |
24 |
-192.6 |
-192.3 |
25 |
-191.1 |
-191.1 |
26 |
-189.6 |
-189.8 |
27 |
-189.4 |
-189.3 |
28 |
-189.2 |
-188.7 |
29 |
-189.7 |
-189.2 |
30 |
-190.2 |
-189.7 |
31 |
-191.3 |
-191.0 |
32 |
-192.4 |
-192.2 |
Aansoek: