| Ketersediaan: | |
|---|---|
| Kuantiti: | |
Piezohannas
20kHz-30khz USBL Transduser Underwater Acoustic Positioning Transducer

Kandungan Pengukuran:
1. Penerimaan Transduser
1.1. Jalur Kekerapan Operasi: 20kHz~30kHz.
1.2. Sensitiviti Penerima: Lebih baik daripada -190dB@24k (riak dalam jalur 3dB).
1.3. Arah: Omnidirectional (3dB).
1.4. Kedalaman Operasi Maksimum: 300m.
1.5. Bilangan Elemen Tatasusunan: 4.
2. Pemancar Transduser
2.1. Jalur Kekerapan Operasi: 20kHz~30kHz.
2.2. Menghantar Respons: Lebih baik daripada 132dB@24k (riak dalam jalur 3dB).
2.3. Directivity: Mendatar omnidirectional, menegak lebih besar daripada 180°.
2.4. Kedalaman Operasi Maksimum: 300m;
Data Pengukuran
1. Penerimaan Transduser
1.1. Kekonduksian dan Kemuatan Keluk



Menerima Sensitiviti
2022-01#接收阵接收灵敏度/dB |
||||
f/kHz |
1# |
2# |
3# |
4# |
20 |
-192.1 |
-191.8 |
-196.5 |
-194.9 |
21 |
-192.9 |
-192.6 |
-197.6 |
-195.2 |
22 |
-193 |
-192.7 |
-198 |
-194.8 |
23 |
-192.9 |
-193.1 |
-198.9 |
-194.5 |
24 |
-192 |
-195.7 |
-200.5 |
-193 |
25 |
-190.5 |
-198.7 |
-201.1 |
-191 |
26 |
-191.3 |
-197.6 |
-198.2 |
-191.3 |
27 |
-193.4 |
-194 |
-196.7 |
-192.6 |
28 |
-193.6 |
-193.4 |
-196.7 |
-193.1 |
29 |
-193.6 |
-193.5 |
-199 |
-193.4 |
30 |
-193.2 |
-193.2 |
-198.5 |
-193.5 |
2022-02#接收阵接收灵敏度/dB |
||||
f/kHz |
1# |
2# |
3# |
4# |
20 |
-192.7 |
-192.8 |
-195.7 |
-193.9 |
21 |
-193.3 |
-193.7 |
-195.5 |
-193.5 |
22 |
-193.6 |
-193.2 |
-195.8 |
-194 |
23 |
-194.6 |
-194.3 |
-197.3 |
-193.4 |
24 |
-193.2 |
-196.7 |
-197.7 |
-192.3 |
25 |
-193.2 |
-195.4 |
-196.1 |
-191.5 |
26 |
-193.2 |
-193.7 |
-194 |
-192.1 |
27 |
-193.6 |
-194.1 |
-195.4 |
-192.5 |
28 |
-193.9 |
-193.1 |
-194.7 |
-192 |
29 |
-194.1 |
-193.6 |
-196.3 |
-192.1 |
30 |
-195 |
-193.9 |
-196 |
-192.1 |
Pemancar Transduser
Kekonduksian dan keluk kemuatan

f/kHz |
2022-01# |
2022-02# |
20 |
135.7 |
136.2 |
21 |
138.6 |
137.3 |
22 |
139.6 |
137.3 |
23 |
138.7 |
140.2 |
24 |
141.3 |
141.7 |
25 |
141.7 |
139.6 |
26 |
138.7 |
137.6 |
27 |
138.3 |
138.5 |
28 |
139.3 |
135.5 |
29 |
135.9 |
134.8 |
30 |
137.7 |
138.8 |
Ujian Tekanan Hidrostatik Selepas menjalani ujian tekanan hidrostatik pada 3MPa/1j, 0MPa/0.25j, 3MPa/1j, dan 0MPa/0.25j, rintangan penebat antara wayar teras transduser dan antara wayar teras dan selongsong luar adalah lebih besar daripada 100MΩ.
Keputusan Pengukuran: Transduser memenuhi spesifikasi teknikal.