Custom Titanium Alloy Ultrasonic Gas Flow Transducer For Ultrasonic Gas Meter

Product Description

200KHz PVDF Housing Ultrasonic Gas Flow Transducer For Ultrasonic Gas Meter



Technical parameters:


Items

Technical Parameters

Image

Name

200KHz ultrasonic transducer

 

Model

PHAU-200-01CA

Frequency

200KHz±5%

Detection Distance

0.101m

Minimum Parallel lmpedance

300Ω±20

Capacitance

850pF±20@1KHz

Sensitivity

No load driving voltage:200VppDistance:0.3m

Echo Amplitude:5mV

Operating Voltage

Peak Voltage500 Vpp

Operating Temperature

-40+80

Pressure

16Kilos or 1.6MPa

Angle

(Beamwidth)Half-power Beam Width@-3dB:10.1°±10%

Sharp Angle:23.9°±10%

Housing Material

titanium alloy

usage

ultrasonic gas flowmeter

Protection Level

IP68

Weight

24.2g±5%(wire length80cm

Wiring Instructions

interface: red: transducer +, white: transducer -, black: shielded wire, ( temperature sensor is optional)

Admittance Curve

Product Structure Diagram

 

 




Block diagram of ultrasonic distance transducer :



Schematic Diagram of Temperature Sensor (model: MF58_502F3470):


Integrated type Cable instruction:   
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +      
White: transducer -         
Black: shielding



2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)

Red and black are temperature sensor wiring



Split type: standard 10m cable, with each additional 50m of cable, the signal attenuation is 6dB

Three-core wiring instructions:                
                        
    Red: Transducer +
     Blue: temperature sensor +
     Black: Public-


 Four-core wiring instructions:

Red: Transducer +                      
Yellow: Transducer-
Blue, black: temperature sensor



Application for Ultrasonic Gas Flowmeter :


Industrial gas flow meters are widely utilised for liquid and water applications, it has long been accepted that clamp on gas flowmeter technology could not be applied to mass gas flow measurement primarily due to fundamental theoretical measurement limits. the transmitted sound energy is received by traditional ultrasonic transducers. However, advances in clamp on gas flow measurement technology and processing have meant that despite lower acoustic impedance levels and higher attenuation levels in most gases, a clamp on gas flow meter can now measure transit times in gases where signal-to-noise ratios are extremely low. It is now possible to measure natural gas, steam, compressed air, hydrogen, compressed air and many more using clamp on flow meters.


Feedback

200Khz Titanium Alloy Ultrasonic Transducer for Ultrasonic Gas Flowmeter

Customizable Ultrasonic RangeTransducer for Ultrasonic Gas Flowmeter

200KHz Titanium Alloy Material Ultrasonic Distance Transducer for Ultrasonic Gas Flowmeter