125KHz Ultrasonic Distance Transducer for Ultrasonic Level Meter

Product Description

125KHz Ultrasonic Distance Transducer for Ultrasonic Level Meter



Technical parameters:


Items

Technical Parameters

Image

Name

125KHz ultrasonic transducer

 

 

 

 

 

Model

PHA-125-02B   

Frequency

125KHz±5%

Detection Distance

0.122m

Minimum Parallel lmpedance

1500Ω±20

Capacitance

450pF±20@1KHz

Sensitivity

 load driving voltage:300VppDistance:0.3mEcho Amplitude:15mV

Operating Voltage

Peak Voltage1200 Vpp

Operating Temperature

-40+80℃

Pressure

≤3Kilos or 0.3MPa

Angle

(Beamwidth)Half-power Beam Width@-3dB:10.1°±10%

Sharp Angle:23.9°±10%

Housing Material

ABS

usage

Ultrasonic level meter, ultrasonic sensor, ultrasonic gas flowmeter

 

Installation Dimension

dimensionø16*19

Protection Level

IP68

Weight

12g±5%(wire length20cm

Wiring Instructions

 interface: red: transducer +, white: transducer -, black: shielded wire, ( temperature sensor is optonal)

Admittance Curve

Product Structure Diagram

 

 

 




Block diagram of ultrasonic distance transducer :



Schematic Diagram of Temperature Sensor (model: MF58_502F3470):


Integrated type Cable instruction:   


1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +      
White: transducer -         
Black: shielding



2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)

Red and black are temperature sensor wiring



Split type: standard 10m cable, with each additional 50m of cable, the signal attenuation is 6dB

Three-core wiring instructions:                
                        
    Red: Transducer +
     Blue: temperature sensor +
     Black: Public-


 Four-core wiring instructions:

Red: Transducer +                      
Yellow: Transducer-
Blue, black: temperature sensor



What Goes into the Making of a Transducer?


The main component of a depth transducer is the piezoceramic element. It is the part that converts electrical pulses into sound waves, and when the echoes return, the piezoceramic element converts the sound waves back into electrical energy. Piezoceramic elements are most often in a disk form,but they may also be in the shape of a bar or a ring. A transducer may contain one element or a series of elements linked together called an array. A transducer is made up of six separate components:


Ultrasonic Level Measurement Application :

 

In non-contact ultrasonic level measurement, the sensor emits ultrasonic pulses in the direction of the medium, which then reflects them back.The elapsed time from emission to reception of the signals is proportional to the level in the tank. Ultrasonic sensors are ideal for simple standard applications, both for liquids and for solids.




Feedback

200Khz Titanium Alloy Ultrasonic Transducer for Ultrasonic Gas Flowmeter

Customizable Ultrasonic RangeTransducer for Ultrasonic Gas Flowmeter

200KHz Titanium Alloy Material Ultrasonic Distance Transducer for Ultrasonic Gas Flowmeter

200KHz Titanium Alloy Material Ultrasonic Transducer for Ultrasonic Gas Flowmeter