100KHz Ultrasonic Transducer for Ultrasonic Flowmeters

Product Description

            100KHz Ultrasonic Transducer for Ultrasonic Flowmeters



Specification:


Items

Technical Parameters

Image

Name

100KHz ultrasonic transducer

 

 

Model

PHA-100-WO   

Frequency

100KHz±5%

Detection Distance

0.152m

Minimum

Parallel lmpedance

320Ω±20

Capacitance

760pF±20@1KHz

 

Sensitivity

Withload Driving Voltage750VppDistance0.3m

Echo Amplitude180 mV

Operating

Voltage

Peak Voltage800 VPP

Operating

Temperature

-40+80℃

Pressure

≤3Kilos or 0.3MPa

 

Angle

(Beamwidth) Half-power Beam Width

@-3dB:7.2°±1

Sharp Angle:7.0°±2

Housing Material

PVDF

 

Usage

Distance measurement

Installation

Dimension

IP68

Protection Level

46g±5%(Length10cm

Wiring instruction

InterfaceRed: transducer+White: transducer-,

Black: shielded wire,( temperature sensor is optional

Admittance Curve

Product Structure Diagram

 

 

 


 

Block diagram of ultrasonic  transducer :


Schematic Diagram of Temperature Sensor:




Integrated type Cable instruction:   

1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)

Red: transducer +      

White: transducer -         

Black: shielding


2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)


Red and black are temperature sensor wiring

 

Ultrasonic water flow meters Application :


Ultrasonic water flow meters measure the speed of fluid passing through the pipe using ultrasound to measure the volumetric flow. In a transit-time ultrasonic liquid flow meter, an ultrasonic signal is transmitted in the direction of the flowing fluid downstream, and then another signal is transmitted against the flowing fluid upstream. In its most basic form, the time for the sonic pulse to travel downstream is compared to the time for the pulse to travel upstream. Using this differential time, the velocity of the following fluid is calculated. Then the meter calculates the volumetric flow rate in the pipe using this fluid velocity. In addition, BTU energy measurement can be derived from the volumetric flow rate and the temperature difference between the hot and cold legs. Clamp-on ultrasonic meters can measure water from outside of the pipe by shooting pulses of sound through the pipe walls, thus having application flexibility and making them suitable for water flow measurements in large pipes.