هیدروفون کروی باند پهن همه جهته 1Hz-480 KHz

پارامترهای فنی:

f/kHz |
Mx/dB |
f/kHz |
Mx/dB |
f/kHz |
Mx/dB |
0.02 |
-214.1 |
1.6 |
-214.4 |
85 |
-217.3 |
0.025 |
-214.1 |
2 |
-214.5 |
90 |
-217.0 |
0.0315 |
-214.4 |
2 |
-214.6 |
95 |
-217.2 |
0.04 |
-214.5 |
2.5 |
-214.6 |
100 |
-217.7 |
0.05 |
-214.1 |
3.15 |
-215.2 |
125 |
-218.4 |
0.063 |
-214.5 |
4 |
-214.3 |
160 |
-218.6 |
0.08 |
-214.4 |
5 |
-214.9 |
200 |
-219.0 |
0.1 |
-214.2 |
6.3 |
-214.6 |
220 |
-219.5 |
0.125 |
-214.0 |
8 |
-214.3 |
240 |
-219.1 |
0.16 |
-214.4 |
10 |
-216.4 |
260 |
-216.8 |
0.2 |
-214.5 |
12.5 |
-215.6 |
280 |
-217.7 |
0.25 |
-214.6 |
16 |
-215.5 |
300 |
-215.9 |
0.315 |
-214.2 |
20 |
-215.0 |
320 |
-218.7 |
0.4 |
-214.2 |
25 |
-215.8 |
340 |
-220.0 |
0.5 |
-214.6 |
31.5 |
-217.1 |
360 |
-224.0 |
0.63 |
-214.1 |
40 |
-215.7 |
380 |
-224.2 |
0.8 |
-214.2 |
50 |
-216.0 |
400 |
-225.5 |
1 |
-214.4 |
63 |
-216.9 |
450 |
-232.1 |
1.25 |
-214.2 |
80 |
-217.2 |
جهت افقی y

جهت گیری عمودی

تست فشار آب ساکن
پس از اینکه هیدروفون تحت آزمایش فشار استاتیک آب 15 مگا پاسکال در ساعت قرار گرفت، هیچ آسیب یا ناهنجاری در ظاهر هیدروفون مشاهده نشد. عملکرد هیدروفون پس از تست فشار طبیعی اندازه گیری شد.
نتایج اندازه گیری
پس از آزمایش، هیدروفون شرایط فنی را برآورده کرد.