20Hz-20kHz Hydrophone Receiving Transducer with Preamplifier
Product Description
20Hz-20kHz Hydrophone Receiving Transducer with Preamplifier
Technical Parameters:
Receiving Sensitivity: Measuring the receiving sensitivity of the transducer within the frequency band of 0.02kHz to 20kHz. The sensitivity should not be lower than -175dB (preamplifier gain 20dB).
Horizontal Directivity: Omnidirectional, measurement frequency 20kHz.
Vertical Directivity: Omnidirectional, measurement frequency 20kHz.
Hydrostatic Pressure: The transducer should be able to withstand a hydrostatic pressure test of 5MPa.
Measurement data
Receiving Sensitivity
f/kHz |
Mx/dB |
0.02 |
-168.5 |
0.025 |
-168.2 |
0.0315 |
-169.0 |
0.04 |
-168.3 |
0.063 |
-168.8 |
0.08 |
-168.5 |
0.1 |
-168.6 |
0.125 |
-168.7 |
0.16 |
-168.6 |
0.2 |
-168.6 |
0.25 |
-168.2 |
0.315 |
-168.9 |
0.4 |
-168.5 |
0.5 |
-168.3 |
0.63 |
-168.5 |
0.8 |
-169.0 |
1 |
-169.1 |
1.25 |
-168.5 |
1.6 |
-168.2 |
2 |
-168.3 |
2.5 |
-169.1 |
3.15 |
-168.5 |
4 |
-167.6 |
5 |
-169.0 |
6.3 |
-169.1 |
8 |
-169.2 |
10 |
-168.8 |
12.5 |
-169.1 |
16 |
-170.1 |
20 |
-171.2 |
Horizontal Directionality
Vertical Directionality
Hydrostatic Pressure Test :After undergoing hydrostatic pressure tests at 5MPa/1h, 0MPa/0.25h, and 5MPa/1h, the transducer showed no visible damage or leakage.
Measurement Results: The transducer meets the technical specifications.
Core Wire Definitions: Red -- Vcc; Yellow -- O+; Black -- GND