Inserted Type 2Mhz Ultrasonic Transducer for Ultrasound Flow Measurement

Product Description

Inserted Type 2Mhz Ultrasonic Transducer for Ultrasound Flow Measurement



Items

Technical Parameters

Image

 Name

Inserted Pipe Flowmeter Transducer

 

Model

PHA-2M-01E

Frequency

2MHz±30KHz

Detection Distance

0.03 2m

Minimum Parallel lmpedance

 

5Ω±20

Capacitance

3200pF±20@1KHz

 

Sensitivity

Probe Driving Voltage:24Vpp

Distance:0.3m

Echo Amplitude:1.01 V

Operating 

Voltage

Peak Voltage150VPP

Operating 

Temperature

-40+80℃

Pressure

≤3 Kilos or 0.3MPa

 

Angle

(Beamwidth)Half-power Beam Width

@-3dB:2°±0.5,

Sharp Angle:4°±1

Housing Material

POM

   Usage

Ultrasonic Flowmeter

Underwater Rangfinder

Installation

Dimension

According to Product Structure Diagram

Protection Level

IP68

Weight

50g±5%(Length:2m

Wiring

Instructions

    Red:transducer+,White:transducer-,Black: shielded wire;

     ( temperature sensor is optional)

Admittance Curve

Product Structure Diagram

 

 


 

Ultrasonic Flow Meter Application:


 An ultrasonic flow meter construction can be done by using upstream and downstream transducers, sensor pipe and reflector. The working principle of ultrasonic flow meter is, it uses sound waves to resolve the velocity of a liquid within a pipe. There are two conditions in the pipe like no flow and flowing. In the first condition, the frequencies of ultrasonic waves are transmitted into a pipe & its indications from the fluid are similar. In the second condition, the reflected wave’s frequency is dissimilar because of the Doppler Effect.



 