Wide-band Low Frequency 2Khz-8khz Transducers Hydroacoustic Transducer
Product Description
Wide-band Low Frequency 2Khz-8khz Transducers Hydroacoustic Transducer
Dimensions :
Size: diameter:278mm,height :156mm
Weight :7kg
Structure diagram of Transducer :
Main indicators:
1. Frequency range: 2~8kHz
2. Transmit voltage response: ≥130dB3.
3. Horizontal directivity: non-directional
4.Cable length:=10m
5. Working depth: ≥500m
Transmitting voltage response and sound source level
f/kHz |
d/m |
UF/VPP |
UJ/mVPP |
M0/dB |
SV/dB |
SL/dB |
2 |
3 |
1120 |
55 |
-205 .3 |
128 .7 |
180 .6 |
3 |
3 |
940 |
80 |
-205 .3 |
133 .4 |
183 .9 |
4 |
3 |
920 |
190 |
-205 .4 |
141 .2 |
191 .5 |
5 |
3 |
920 |
270 |
-205 .4 |
144 .3 |
194 .5 |
6 |
3 |
920 |
260 |
-205 .5 |
144 .1 |
194 .3 |
7 |
3 |
910 |
220 |
-205 .5 |
142 .7 |
192 .9 |
8 |
3 |
970 |
180 |
-205 .5 |
140 .4 |
191 .1 |
Receiving Sensitivity
Chart 2-1 Receiving Sensitivity
f/kHz |
01# |
02# |
03# |
2 |
-178 .3 |
-177 .5 |
-178 .1 |
3 |
-178 .9 |
-178 .9 |
-176 .8 |
4 |
-181 .5 |
-181 .2 |
-179 .1 |
5 |
-177 .3 |
-175 .7 |
-177 .6 |
6 |
-174 .4 |
-173 .9 |
-174 .8 |
7 |
-179 .1 |
-176 .6 |
-179 .3 |
8 |
-182 .9 |
-181 .2 |
-181 .4 |
Horizontal directivity
Vertical Directivity
Cp-G Curve:
Hydrostatic pressure test
chart 6-1 pressure test
Measurement curve |
Lasting time |
1H |
0 .5H |
1H |
0 .5H |
Hydrostatic pressure |
5MPa |
0 |
5 .25MPa |
0 |
|
After pressure test |
|||||
Insulation Resistance |
1# |
≥500MΩ |
|||
2# |
≥500MΩ |
||||
3# |
≥500MΩ |
||||