3Mh HIFU Ceramics Transducer for Beauty Machine

Product Description

            3Mh HIFU Ceramics Transducer for Beauty Machine


WuHan Piezohannas Tech.Co .,Ltd is a manufactuer of piezoelectric ceramics ,ultrasonic transducers and some other ultrasonic deivce with strong technology force.With a quality management system and research & development sector,our products are extensively used in most applications.




Piezo Ceramics Description:


OD:Φ25mm
R45mm
Material:PZT-82
Frequency:3Mhz
Application: Beauty Machine


Performance Parameter:


Fs(Hz):89936

Fp(Hz):104720

Kp:0.578

ft(MHZ):2.997

C(pf): 7550





Application of HIFU Piezo Ceramic:


Ultrasonic focus ceramic (HIFU) is widely used in the beauty machine, weight loss medical industry and liposonix,ultra Shape.On behalf of the product is this year the rise of the ultrasonic knife, Liposonix slimming Instrument,Ultra Shape slimming instrument.



Standard Size of HIFU Piezo Ceramic:


Working Frequency : 1 ~ 10 MHz (Selectable)

Aperture size : Diameter 20 ~ 70mm(Selectable)

Focal length: 10 ~ 100 mm (Selelctable)

Strong Electrode: Silvering ,Nickel, Titanium Alloys


Typical value of "Hard" PZT materials performance:

 

Hard" PZT materials



PZT-41

PZT-42

PZT-43/4D

PZT-82

PBaS-4

Dielectric Constant

ɛTr3


1050

1250

1420

1100

1900









Coupling factor 

KP


0.58

0.58

0.58

0.52

0.59


K31


0.32

0.33

0.34

0.3

0.34


K33


0.66

0.67

0.68

0.57

0.68


Kt


0.48

0.48

0.48

0.4

0.49

Piezoelectric coefficient

d31

10-12m/v

-106

-124

-138

-100

-160


d33

10-12m/v

260

280

300

240

380


g31

10-3vm/n

-11.4

-11.2

-11

-10.3

-9.5


g33

10-3vm/n

28

25.3

24

25

22.6

Frequency coefficients

Np


2280

2200

2160

2280

2200


N1


1671

1613

1583

1671

1613


N3


1950

1900

1875

1950

1850


Nt


2250

2200

2200

2300

2200

Elastic compliance coefficient

Se11

10-12m2/n

11.8

12.7

13.2

11.6

13.2

Machanical quality factor

Qm


1000

800

600

1200

2200









Dielectric loss factor

Tg δ

%

0.3

0.4

0.5

0.3

0.5

Density

ρ

g/cm3

7.5

7.5

7.5

7.6

7.5

Curie Temperature

Tc

°C

320

320

320

310

310

Young's modulus

YE11

<109N/m3

85

79

76

86

76

Poison Ratio



0.3

0.3

0.3

0.3

0.33



Application:


 

  



Feedback

4Mhz High Focus Piezoelectric Ceramics for Medial Aesthetic

250 KHz HIFU Transducer for Medical Laser Equipment

250 KHz Ultrasonic High Focusing Piezo for Medical Equipment

250 KHz High Focusing Piezo Ceramic Transducer for Medical Equipment

3Mh High Focusing Hifu Ceramics Transducer for Medical Aesthetic