| Infhaighteacht: | |
|---|---|
| Cainníocht: | |
PZ1000K00
Piezohannas
PZ1000K00
Criostail Diosca Piezoceramic Ultrasonach Leighis le haghaidh Trealamh Diagnóiseacha
Is WuHan Piezohannas Tech.Co., Ltd manufactuer de criadóireacht piezoelectric, trasducers ultrasonaic le fórsa láidir teicneolaíochta. Le córas bainistíochta cáilíochta agus taighde agus earnáil forbartha, ár gcuid táirgí a úsáidtear go forleathan i bhfeidhmchláir is mó.





l. Cur síos ar ceirmeach Piezo :
Céimseata |
Méid (mm) |
Caoinfhulaingt |
Dioscaí Piezo |
Trastomhas: 3 go 200 |
Caoinfhulaingt de réir na heilimintí piezoelectric Caighdeán tionsclaíoch. |
Tiús: 0.2-25 |
||
Feadáin Piezo |
Fad: 1-100 |
|
OD: 6-180 |
||
ID: 5-150 |
||
Balla: 0.5-15 |
||
Plátaí Piezo |
Fad: 1-200 |
|
Leithead: 1-200 |
||
Tiús: 0.2-25 |
||
Sféar Piezo |
OD: 6-160 |
|
ID: 4-150 |
||
Balla: 1-10 |
||
Fáinní Piezo |
OD: 3-180 |
|
ID: 1-150 |
||
Tiús: 0.2-25 |
||
Do Gach Méid |
Maoile |
± 0.03 |
Concentricity |
± 0.10 |
|
Perpendicularity |
± 0.10 |
|
Comhthreomhaireacht |
± 0.05 |
Ábhar Bog PZT:
Ábhair PZT ' Bog ' |
An cineál ábhar bog |
||||||||
Airíonna |
PSnN-5 |
PLiS-51 |
PZT-51 |
PZT-52 |
PZT-53 |
PZT-5H |
PZT-5X |
||
Tairiseach Tréleictreach |
ɛTr3 |
1600 |
2000 |
2200 |
2400 |
2600 |
3200 |
4500 |
|
Fachtóir cúplála |
KP |
0.6 |
0.62 |
0.62 |
0.63 |
0.64 |
0.68 |
0.7 |
|
K31 |
0.35 |
0.35 |
0.35 |
0.35 |
0.36 |
0.38 |
0.4 |
||
K33 |
0.68 |
0.7 |
0.68 |
0.7 |
0.7 |
0.76 |
0.77 |
||
Kt |
0.5 |
0.52 |
0.5 |
0.5 |
0.5 |
0.52 |
0.53 |
||
Comhéifeacht piezoelectric |
d31 |
10-12m/v |
-170 |
-197 |
-186 |
-204 |
-227 |
-275 |
-300 |
d33 |
10-12m/v |
400 |
450 |
500 |
520 |
550 |
620 |
750 |
|
g31 |
10-3vm/n |
-12 |
-11.1 |
-9.6 |
-9.8 |
-9.9 |
-9.7 |
-7.5 |
|
g33 |
10-3vm/n |
28 |
25.4 |
25.6 |
24.5 |
23.9 |
22 |
18.8 |
|
Comhéifeachtaí minicíochta |
Np |
2000 |
1920 |
1980 |
1980 |
1960 |
1900 |
1960 |
|
N1 |
1466 |
1407 |
1451 |
1451 |
1437 |
1393 |
1437 |
||
N3 |
1825 |
1925 |
1900 |
1900 |
1755 |
1550 |
1800 |
||
Nt |
2100 |
2100 |
2150 |
2150 |
2150 |
2100 |
2200 |
||
Comhéifeacht comhlíonta leaisteacha |
Se11 |
10-12m2/n |
16.6 |
18 |
16.7 |
17 |
17.4 |
18 |
19 |
Fachtóir cáilíochta machanical |
Qm |
85 |
80 |
80 |
75 |
75 |
70 |
65 |
|
Fachtóir caillteanas tréleictreach |
Tg δ |
% |
2 |
2 |
2 |
2 |
2 |
2 |
2 |
Dlús |
ρ |
g/cm3 |
7.5 |
7.5 |
7.6 |
7.6 |
7.6 |
7.5 |
7.5 |
Teocht Curie |
Tc |
°C |
350 |
345 |
270 |
270 |
270 |
230 |
165 |
Modal Young |
TÁ11 |
<109N/m2 |
60 |
56 |
60 |
59 |
57.5 |
56 |
53 |
Cóimheas Nimhe |
0.36 |
0.36 |
0.36 |
0.36 |
0.36 |
0.36 |
0.39 |
||
Ábhar Crua PZT:
Crua ' ábhair PZT |
PZT-41 |
PZT-42 |
PZT-43/4D |
PZT-82 |
PBaS-4 |
||
Tairiseach Tréleictreach |
ɛ T r3 |
1050 |
1250 |
1420 |
1100 |
1900 |
|
Fachtóir cúplála |
K P |
0.58 |
0.58 |
0.58 |
0.52 |
0.59 |
|
K31 |
0.32 |
0.33 |
0.34 |
0.3 |
0.34 |
||
K33 |
0.66 |
0.67 |
0.68 |
0.57 |
0.68 |
||
K t |
0.48 |
0.48 |
0.48 |
0.4 |
0.49 |
||
Comhéifeacht piezoelectric |
d31 |
10-12m/v |
-106 |
-124 |
-138 |
-100 |
-160 |
d33 |
10-12m/v |
260 |
280 |
300 |
240 |
380 |
|
g31 |
10-3vm/n |
-11.4 |
-11.2 |
-11 |
-10.3 |
-9.5 |
|
g33 |
10-3vm/n |
28 |
25.3 |
24 |
25 |
22.6 |
|
Comhéifeachtaí minicíochta |
N lch |
2280 |
2200 |
2160 |
2280 |
2200 |
|
N1 |
1671 |
1613 |
1583 |
1671 |
1613 |
||
N3 |
1950 |
1900 |
1875 |
1950 |
1850 |
||
N t |
2250 |
2200 |
2200 |
2300 |
2200 |
||
Comhéifeacht comhlíonta leaisteacha |
S e11 |
10-12m 2/n |
11.8 |
12.7 |
13.2 |
11.6 |
13.2 |
Fachtóir cáilíochta machanical |
Qm |
1000 |
800 |
600 |
1200 |
2200 |
|
Fachtóir caillteanas tréleictreach |
Tg δ |
% |
0.3 |
0.4 |
0.5 |
0.3 |
0.5 |
Dlús |
ρ |
g/cm3 |
7.5 |
7.5 |
7.5 |
7.6 |
7.5 |
Teocht Curie |
Tc |
°C |
320 |
320 |
320 |
310 |
310 |
Modal Young |
Y E11 |
<10 9N/m3 |
85 |
79 |
76 |
86 |
76 |
Cóimheas Nimhe |
0.3 |
0.3 |
0.3 |
0.3 |
0.33 |
Feidhm Trealamh Ultrafhuaime Diagnóiseacha:
Is éard is trealamh diagnóiseach ultrafhuaime ann ná trealamh a chuireann tonnta ultrasonaic i bhfeidhm ar rud agus a mhapálann a chruth inmheánach bunaithe ar na tonnta rebounding. Sa réimse leighis, úsáidtear é chun orgáin inmheánacha, féatas agus codanna eile de chorp an duine a scrúdú. Ar dtús, níorbh fhéidir tonnta ultrasonaic a tharchur ach i dtreo amháin, rud a fhágann nach bhféadfaí ach íomhánna déthoiseacha, fós a tháirgeadh. bhí sé indéanta tonnta ultrasonaic a sheoladh i bhfoirm lucht leanúna, rud a chuir ar chumas íomháú fíor-ama a dhéanamh ar ghluaiseachtaí orgáin inmheánacha nó fhéatas. Le déanaí, le dul chun cinn i dteicneolaíochtaí próiseála íomhá, is féidir íomhánna tríthoiseach níos beoga agus níos soiléire a tháirgeadh. Toisc go n-úsáideann trealamh ultrafhuaime diagnóiseacha tonnta fuaime in ionad radaíochta, ní bhíonn aon bhagairt ar nochtadh radaíochta do na hothair. Ina theannta sin, nach bhfuil aon ullmhóidí ilchasta ag teastáil uaidh, tá buntáistí aige mar thástáil othar níos éasca agus nach bhfuil chomh pianmhar. Ar an láimh eile, ós rud é nach ndéanann tonnta ultrasonaic iomadú trí chnámha nó aer, níl an trealamh oiriúnach chun na scamhóga, na boilg agus na n-intestí a bhreathnú, ina bhfuil aer ar fad.