Low Frequency 300Hz-10000Hz Acoustic Transducer Hydrophone Underwater Projector
Product Description
Low Frequency 300Hz-10000Hz Acoustic Transducer Hydrophone Underwater Projector
Measurement Details:
1.1. Operating Frequency Band: 0.3kHz-10kHz;
1.2. Sound Source Level:
0.3kHz-1kHz: ≥160dB, maximum not less than 180dB;
1kHz-1kHz: ≥170dB, maximum not less than 185dB;
2kHz-10kHz: ≥180dB.
1.3. Directivity: Horizontal omnidirectional, vertical opening angle not less than 85°.
1.4. Hydrostatic Pressure: 1MPa.
2. Measurement Data
2.2.1. Conductance and Capacitance Curves
Sound source level
f/kHz |
d/m |
U发/Vpp |
U收/mVpp |
M0/dB |
SL/dB |
0.3 |
0.666 |
1645 |
8.875 |
-218.2 |
164.6 |
0.4 |
0.666 |
1645 |
36.25 |
-218.2 |
176.8 |
0.43 |
0.666 |
2138 |
56.875 |
-218.2 |
180.7 |
0.5 |
0.666 |
1645 |
26.875 |
-218.2 |
174.2 |
0.6 |
0.666 |
1645 |
18 |
-218.2 |
170.7 |
0.7 |
0.666 |
1645 |
15.375 |
-218.2 |
169.4 |
0.8 |
0.666 |
1645 |
14.5 |
-218.2 |
168.9 |
0.9 |
0.666 |
1645 |
27.125 |
-218.2 |
174.3 |
1 |
0.666 |
1645 |
18.375 |
-218.2 |
170.9 |
1.1 |
0.666 |
1585 |
21.5 |
-218.3 |
172.4 |
1.2 |
0.666 |
1585 |
31.375 |
-218.3 |
175.7 |
1.3 |
0.666 |
1585 |
48 |
-218.3 |
179.4 |
1.4 |
0.666 |
1585 |
65.375 |
-218.3 |
182.0 |
1.5 |
0.666 |
1585 |
83.25 |
-218.3 |
184.1 |
1.6 |
0.666 |
1585 |
94.75 |
-218.3 |
185.3 |
1.7 |
0.666 |
1585 |
88 |
-218.3 |
184.6 |
1.8 |
0.666 |
1585 |
73.25 |
-218.3 |
183.0 |
1.9 |
0.666 |
1585 |
62 |
-218.3 |
181.6 |
2 |
0.666 |
1585 |
55.5 |
-218.4 |
180.7 |
2 |
0.795 |
1160 |
46 |
-218.5 |
180.7 |
2.5 |
0.795 |
1160 |
86 |
-218.5 |
186.2 |
3 |
0.795 |
1160 |
111 |
-218.6 |
188.5 |
4 |
0.795 |
290 |
58.5 |
-218.7 |
183.0 |
5 |
0.795 |
290 |
90 |
-218.7 |
186.8 |
6 |
0.795 |
290 |
71 |
-218.7 |
184.7 |
7 |
0.795 |
290 |
39 |
-218.7 |
179.5 |
8 |
0.795 |
290 |
50 |
-218.7 |
181.7 |
9 |
0.795 |
290 |
56 |
-218.8 |
182.7 |
10 |
0.795 |
290 |
52 |
-218.8 |
182.1 |
Horizontal directivity
Vertical directivity
Hydrostatic Pressure Test:
After undergoing hydrostatic pressure tests at 1 MPa/1 hour, 1 MPa/0.25 hour, 1 MPa/1 hour, and 0 MPa/0.25 hour, the transducer's appearance remained intact and normal, and the insulation resistance between the transducer cores was greater than 200 MΩ.
Measurement Results:
All transducers met the technical specifications.