80Khz Ultrasonic Transducer Distance Measurement with Temperature Sensor
Product Description
80Khz Ultrasonic Transducer Distance Measurement with Temperature Sensor
Technical parameters:
Test content: KDYA-80-04B transducer;
Test conditions:No-load driving voltage: 300Vpp;
Number of driving pulses: 15;
Test distance: 0.6m;
Test method: self-transmit self-received;
Receiving signal: Echox10;
Test Results:
Dimension:
The test results of the transducer according to the "test conditions" are shown in Table 1 below:
Table 1: Transducer test results
Sendig End |
Center Frequency(KHz) |
Echo Signal (mV) |
01 |
86 |
200 |
02 |
83 |
194 |
03 |
86 |
216 |
04 |
83 |
148 |
05 |
83 |
190 |
06 |
83 |
180 |
07 |
86 |
190 |
Admittance Chart