Availability: | |
---|---|
Quantity: | |
PHA-200-01X
Piezohannas
PHA-200-01X
Titanium-housed Ultrasonic Transducer Sensor for Ultrasonic Gases Flowmeters
Parameters:
Items | Technical Parameters | Image | |
Name | 200KHz ultrasonic transducer |
| |
Model | PHA-200-01X | ||
Explosive gas atmospheres | Work normally | ||
Active zone diameter | 15 mm | ||
Frequency
| 200KHz±5% | ||
Recommended range | 0.10~1.5m | ||
Minimum Parallel lmpedance | 360Ω±20% | ||
Capacitance | 500pF±20% @1KHz | ||
Sensitivity | Driving Voltage:800Vpp,Distance:0.6m, Echo Amplitude:40mV | ||
Operating voltage | Peak Voltage<1000 VPP | ||
Operating Temperature | -40~+80℃ | ||
Pressure | 16Kilos or 1.6MPa | ||
Usage | (Beamwidth) Half-power Beam Width@-3dB:7°±2, Sharp Angle:18°±4 | ||
Housing Material | titanium alloy | ||
Application | Ultrasonic Gas Flow Meter | ||
Installation Dimension | customized according to customer’s requirements | ||
Protection Level | IP68 | ||
Weight | 20g±5%( Length:20cm) | ||
Wiring Instructions | Integrated interface:Red+,White-,Black: shielded wire ( default : without temperature sensor)
| ||
Admittance Curve | Product Structure Diagram | ||
|
|
Block diagram of ultrasonic transducer :
Schematic Diagram of Temperature Sensor:
Integrated type Cable instruction:
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +
White: transducer -
Black: shielding
2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)
Red and black are temperature sensor wiring
Ultrasonic Gas Flow Meters Application:
Titanium-housed Ultrasonic Transducer Sensor for Ultrasonic Gases Flowmeters
Parameters:
Items | Technical Parameters | Image | |
Name | 200KHz ultrasonic transducer |
| |
Model | PHA-200-01X | ||
Explosive gas atmospheres | Work normally | ||
Active zone diameter | 15 mm | ||
Frequency
| 200KHz±5% | ||
Recommended range | 0.10~1.5m | ||
Minimum Parallel lmpedance | 360Ω±20% | ||
Capacitance | 500pF±20% @1KHz | ||
Sensitivity | Driving Voltage:800Vpp,Distance:0.6m, Echo Amplitude:40mV | ||
Operating voltage | Peak Voltage<1000 VPP | ||
Operating Temperature | -40~+80℃ | ||
Pressure | 16Kilos or 1.6MPa | ||
Usage | (Beamwidth) Half-power Beam Width@-3dB:7°±2, Sharp Angle:18°±4 | ||
Housing Material | titanium alloy | ||
Application | Ultrasonic Gas Flow Meter | ||
Installation Dimension | customized according to customer’s requirements | ||
Protection Level | IP68 | ||
Weight | 20g±5%( Length:20cm) | ||
Wiring Instructions | Integrated interface:Red+,White-,Black: shielded wire ( default : without temperature sensor)
| ||
Admittance Curve | Product Structure Diagram | ||
|
|
Block diagram of ultrasonic transducer :
Schematic Diagram of Temperature Sensor:
Integrated type Cable instruction:
1.Wiring instruction of transducer: interface (3pin, 2.54mm terminal)
Red: transducer +
White: transducer -
Black: shielding
2.Cable Instruction of Temperature Sensor: interface (3pin, 2.0mm terminal)
Red and black are temperature sensor wiring
Ultrasonic Gas Flow Meters Application: