I. Packing List

One ultrasonic cleaning machine

One power cable

One copy of product operation manual

(*One cleaning basket (optional))

 

Please verify your product pack for integrity against the aforesaid list. For any damage to the packing or missing of any component, immediately contact your dealer.

 

II. Operating Principle

 

Ultrasonic cleaning is based on such a principle that, high frequency oscillation signals from ultrasonic wave generator is converted into high-frequency mechanical oscillation, which is transferred into the medium - solution, where the waves are radiated forwards in an alternative density to make the liquid flow and generate tens of thousands of tiny air bubbles in diameter of 50~500μm which keep vibrating under the effect of the acoustic field, forming and growing in negative pressure areas through which the ultrasound waves travel vertically and rapidly enlarging and suddenly closing in positive pressure areas when acoustic pressure reaches to a certain value; such closure of air bubbles generates shock waves and impose over one thousand of atmospheric pressure around them, and thus breaks down and disperse insoluble dirt around the cleaning fluid, and any solid grains covered by oily dirt and attached to the surface of the work piece are removed off when the oily dirt is emulsified, so that the work piece is cleaned and sterilized.

 

III. Product Features

 

1.Higher ultrasound wave power conversion ratio, faster cleaning and times or scores of times higher cleaning efficiency than conventional method.

2.High cleaning performance, excellent cleanliness and effective cleaning of even any inaccessible parts such as hole and seam.

3.Sterilization of work piece, dissolution of organic contaminant and corrosion protection.

4.Fabrication of high-quality embossed stainless steel with excellent rust protection and aesthetical appearance; cleaning tank made of quality SUS304 stainless steel pressed formed free of welding seam and watertight.

5.Cleaning temperature adjustable between 20~80℃, operating time displayed and controlled digitally with LED and ranging between 0~30 minutes to meet various cleaning needs. 

6.Drain and heat dissipater provided in models of 6L or larger in user-friendly design for quick discharge of waste water after cleaning.

7.Cleaning basket with mesh screen fabricated of stainless steel argon arc welded for easy use.

8.High-quality key component imported overseas for easy use.

9.Safe and reliable cleaning process without need of manual intervention and free of damage to surface of work piece, using less solvent, heat energy, space occupation and manpower.


IV. Technical Parameters

 

Model

Internal Dimensions (L*W*H)

External Dimensions (L*W*H)

Volume (L)

Net Weight (KG)

Ultrasonic Capacity (W)

Frequency (KHz)

Heating Capacity (W)

Time (Min.)

Heating Temperature (℃)

PH-4120

240*135*100

268*170*243

3.2

3.9

120

40

100

0~30

20~80

PH-4180

300*150*100

325*170*243

4.5

4.7

180

200

PH-4180L

302*150*150

325*178*290

6.8

5.1

PH-4240

300*240*100

368*270*253

7

6.3

240

300

PH-4240L

300*240*150

368*270*305

11

6.9

PH-4360

330*300*150

397*335*317

15

9.1

360

400

PH-4360L

330*300*200

397*335*368

20

9.8

PH-4480

500*300*150

560*320*303

22

11.4

480

500

PH-4600

500*300*200

560*322*385

30

13

600

500

 

V. Scope of Application

1.Machinery: Removal of oil/grease on parts and components, cleaning of engine, carburetor and automobile parts and components, filter, and filter mesh.

2.Surface treatment: Removal of oil and rust before galvanic coating, cleaning and phosphating process before ion plating, removal of accumulated carbon, scale and polishing paste, activation of surface of work piece.

3.Instrumentation: cleaning of measuring tools and fine cleaning of precision parts prior to assembly.

4.Electronics: Removal of rosin and welding spots on printing circuit board and cleaning of HV contacts and other electronic parts.

5.Medical care: Cleaning, disinfection and sterilization of medical devices and lab glassware.

6.Semiconductor: Fine cleaning of semiconductor chips.

7.Timepiece and jewelry: Removal of grease, dirt, scale and polishing paste.

8.Chemicals and biologicals: Cleaning of lab glassware. 

9.Optics: Cleaning of optical components and lens.

10.Textile dyeing and finishing: Cleaning of spinning spindle and spinneret.

11.Petrochemicals: Cleaning of metal filter mesh, chemical containers and exchanger.


VI.Installation and Preparation

 

1.After unpacking, check whether any part gets loose.

2.Place the machine horizontally at a well-ventilated and dry location.

3.Select appropriate detergent, cleaning water or other solution based on properties of work piece to be cleaned.

4.Properly and firmly connect the plug to a three-pin power socket which is grounded reliably to ensure safety.

 

VII. Operation Instructions

 

Picture of Product

 



Operation Instructions

1.Load cleaning fluid into the tank and connect the power supply (which shall be grounded reliably). After power-on, current actual temperature is displayed and the default temperature is 0℃. The ultrasound wave operating time is 3 minutes by default.

2.Adjustment of ultrasound wave operating duration: Increase the duration by one second by each press on Duration Increase (press down and hold the button to increase consecutively). Decrease the duration by one second by each press on Duration Decrease (press down and hold the button to decrease consecutively).

3.Adjustment of operating temperature: Increase the temperature by one degree by each press on Temperature Up (press down and hold the button to increase consecutively). Decrease the temperature by one degree by each press on Temperature Down (press down and hold the button to decrease consecutively). When the set temperature is higher than current ambient temperature, the heating system is started and the heating indicator light turns on. When the set temperature is lower than current ambient temperature, the heating system stops operating.  

4.After the operating time and temperature have been set, press ON/OFF button to start operation, and press ON/OFF again to stop operation.

 

VIII. Factors Influencing Performance

 

1.Ultrasonic wave power density: Higher power density results in better cleaning performance and higher cleaning speed. Higher power density is appropriate for cleaning of work piece with stubborn dirt, and lower power density is suitable for any precision work piece (generally ultrasonic power density ranges between 0.01-0.02w/ml).

2.Ultrasonic frequency: Lower frequency results in better cavitation performance. Higher frequency contributes to better refraction/ reflection performance. Lower frequency should be applied for cleaning of simple surface while higher frequency for  cleaning of complex surface with deep or inaccessible hole. (80KHz, 130KHz)

3.Cleaning temperature: Ultrasound wave will present the best cavitation performance at a temperature range between 40~50℃. Higher cleaning temperature facilitates breakdown of dirt, while a temperature above 70℃~80℃ may impair effect of ultrasound wave and deteriorate cleaning performance.

4.Cleaning duration: Longer cleaning duration presents better cleaning performance (except for special material).

5.Other influential factors include type and properties of cleaning fluid and the dirt to be removed.

 

IX. Maintenance

 

This machine shall be used, maintained by dedicated personnel and a full check on the equipment shall be performed regularly.

1.Check the power supply and line connections for any looseness, overheating, damp absorption or poor contact.

2.Inspect sealing of the bottom board of cleaning tank for any leakage. Check the joint between drain pipe and cleaning tank for leakage.

3.For looseness of ultrasound wave converted or burnout of power tube, contact the manufacturer immediately.

4.The ultrasound wave equipment shall be operated and stored at well-ventilated, dry and clean place to facilitate good performance and long service life.

 

X. Troubleshooting

 

Problem  

Solution

Failure   of Ultrasonic Wave

(1) Check whether the power voltage meets   the rated value, or fluctuate significantly.

(2) Check the power socket, switch,   connection terminal and joint for looseness.

(3) Inspect the fuse for any abnormal   flash or noise.

(4) Check the power tube for any damage.

Weak   ultrasound wave or operation with whistle

(1) Check whether the energy converter is   affected with damp or the insulation resistance is normal.

(2) Inspect the power cable for any   external damage or damp absorption.

(3) Check whether the power voltage is   normal.

(4) Inspect whether the energy converter   get loose or there is any shock absorption material or work piece under the   tank.

(5) Check whether the cleaning fluid is   in normal temperature or any improper operation was performed.

Electric   leakage (distinguish between failure of the main unit and that of generator   by removing the HF connector and checking insulation)

(1) Check whether the power cable is   affected with damp, or the supply voltage is in frequent excessive   fluctuation.

(2) Check whether the machine is affected   with damp and thereby corroded.

(3) Check the cable tray to each   component is damaged, loosened or broken.

(4) Check whether the heating plate is   destroyed or broken.

(5) Check whether the ground wire is in   good condition.

Arc   strike or abnormal flash or noise

(1) Poor isolation or damp absorption of   oscillator.

(2) Check whether any connection or   terminal gets loosened or in    poor   contact.

If the problem cannot be removed, contact our service center or return the equipment to the HQ or your local office for handling.



Previous: 
Next: 

Hot Products

  • Dimensions:60x5mm Resonant frequency fr: 420 KHz±2%      Electromechanical coupling coefficient K33:≥58% Resonant impedance Zm: ≤45 Ω Static capacitance Cs: 5100pF±14%@1kHz Application: Piezo transducer for milk analysis, Piezo transducer for vibration, transducer for matter dispersion, sonar transducer Ultrasonic sensor, vibration sensor, wall thickness sensor, material stress sensor, pressure sensor, energy electricity harvesting, compression sensor, piezo expansion sensor and others.
    $0
    $0
  • We can offer 2Mhz,4Mhz,6Mhz TCD Doppler Sensor .The shape of shell can be customized based on your requirements. Application:This probe is used for craniocervical doppler flowmeter,it is good anti-interference ability and high sensitivity,which has been integrated with many TCD equipment manufacturer.
    $0
    $0
  • We can offer the 5Mhz,8Mhz,10Mhz,13Mhz a-ultrasound sensor Application : The sensor used for measuring thickness of fat of Pet or livestock, and measuring distance or measuring thickness in ophthalmology.
    $0
    $0
  • Dimension: Outer Dimension: 18mm Inter Dimension:  15mm Height:  15mm Features of piezoelectric crystal: 1. Low impedance 2. The waveform is stable 3. High electromechanical conversion efficiency 4. Low dielectric loss 5. Heat a small 6. Big spray volume 7. The life of more than 5000 hours 8. Acid corrosion
    $0
    $0
  • Dimension : OD60mm xID30mm x Thi10mm For ultrasonic welding machine,our clients often order 60 x30 x10mm,50 x20 x6.5mm piezo ring ,they are in stock all in our factory. Please contact us as soon if any requirements.
    $0
    $0
  • Dimension : OD50mm xID20mm x Thi6.5mm For ultrasonic welding machine,our clients often order 60 x30 x10mm,50 x20 x6.5mm piezo ring ,they are in stock all in our factory. Please contact us as soon if any requirements.
    $0
    $0
  • Hemisphere piezo: Dimension: Diameter : 50mm OD of Hole:8mm Wall thickness : 2mm Features of high temperature piezoceramic: 1. Low impedance 2. The waveform is stable 3. High electromechanical conversion efficiency 4. Low dielectric loss 5. Heat a small 6. Big spray volume 7. The life of more than 5000 hours 8. Acid corrosion
    $0
    $0
  • Dimension (diameter×thickness):10mmx2mm Features of piezoelectric crystal: 1. Low impedance 2. The waveform is stable 3. High electromechanical conversion efficiency 4. Low dielectric loss 5. Heat a small 6. Big spray volume 7. The life of more than 5000 hours 8. Acid corrosion
    $0
    $0
  • Dimension (diameter×thickness):16mmx0.4mm Features of piezoelectric crystal: 1. Low impedance 2. The waveform is stable 3. High electromechanical conversion efficiency 4. Low dielectric loss 5. Heat a small 6. Big spray volume 7. The life of more than 5000 hours 8. Acid corrosion
    $0
    $0
  • Hemisphere piezo: Dimension: Diameter : 15mm OD of Hole:4mm Wall thickness : 1mm Features of high temperature piezoceramic: 1. Low impedance 2. The waveform is stable 3. High electromechanical conversion efficiency 4. Low dielectric loss 5. Heat a small 6. Big spray volume 7. The life of more than 5000 hours 8. Acid corrosion
    $0
    $0
  • About ultrasonic distance transducer, we can offer transducer that can detect 1M,3M,4M,5M,8M,12M,20M,30M,50M, Also we can accpet customization.
    $0
    $0
  • About ultrasonic distance transducer, we can offer transducer that can detect 1M,3M,4M,5M,8M,12M,20M,30M,50M, Also we can accpet customization.
    $0
    $0
  • Size: 54.5x47x40mm Application: Underwater communication device, Hydrophone , Sonar.
    $0
    $0
Hubei Hannas Tech Co.,Ltd  is a professional piezoelectric ceramics and ultrasonic transducer manufacturer, dedicated to ultrasonic technology and industrial applications.                                    
 

RECOMMEND

CONTACT US

Add: No.302 Innovation Agglomeration Zone, Chibi Avenu ,Chibi City, Xianning, Hubei Province,China
E-mail: sales@piezohannas.com
Tel: +86 07155272177
Phone: +86 +18986196674         
QQ: 1553242848 
Skype: live:mary_14398
​        
Copyright 2017  Hubei Hannas Tech Co.,Ltd All rights reserved. 
Products